Product Model
DRT2-OD08C-1

Selling Points
- 1High Output Current Control: Control loads up to 1.5 A per point without relays, reducing wiring costs.
- 2Robust Troubleshooting: Equipped with Smart Slave functions for powerful preventative maintenance and error detection.
- 3IP67 Protection: Dust-proof and drip-proof construction ensures reliable operation in harsh environments.
- 4Sensor Power Supply Protection: Detects short-circuits and notifies the Master, ensuring stable sensor operation.
- 5Efficient Power Supply: No power supply wiring required for input devices, simplifying installation and reducing complexity.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Mounting | Panel Mount | Terminal Type | M12 Connector |
Input Voltage | 24 VDC | Output Type | DC PNP |
Number of Output Points | 8 | Number of Outputs Per Common | 8 |
Output Voltage | 24 VDC | Output Current Per Point | 1.5 A |
Output Current Per Common | 8.0 A | Output On Time | 0.5 ms |
Output Off Time | 1.5 ms |
Specifications may be subject to change without notice