Product Model
XW2D-50Y6

Selling Points
- 1Reduced Mounting Area: Mounting area reduced by 35% compared to 40-pole units, contributing to downsized control panels and automatic equipment.
- 2Built-in Bleeder Resistance: Equipped with built-in bleeder resistance for inputs to units with Fujitsu or MIL connectors.
- 3DIN Track Compatibility: Compatible with DIN Track and features a unique DIN Track lock that maintains the open status during attachment and removal.
- 4Easy Terminal Counting: Screw terminals arranged by color in groups of five to simplify counting terminal numbers.
- 5High Reliability: Rated for 1A current, 125VAC voltage, and 100MΩ insulation resistance, ensuring high reliability in various applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Mounting | DIN or Screw | Input Current | 1 A |
Input Type | NPN | Number of Output Points | 16 |
Output Type | NPN | Output Voltage | 12 to 24 VDC |
Input Voltage | 125 VAC, 24 VDC |
Specifications may be subject to change without notice