Product Model

ACS880-M04-044A-5

In Stock
Last updated: 2025/4/20
ABB ACS880-M04-044A-5

Selling Points

  • 1Equipped with safe torque off (STO) and optional safety functions module for enhanced application safety.
  • 2Suitable for high-performance applications with direct torque control (DTC) and adaptable IEC 61131-3 programming capabilities.
  • 3Includes an energy optimizer and energy efficiency information for monitoring and saving energy.
  • 4Supports various fieldbus protocols, including Modbus RTU, and PROFIsafe over PROFINET connectivity to PLC.
  • 5Offers intuitive control panels and PC tools for easy drive commissioning and replacement.
Product Details
ACS880-M04-044A-5
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Weight
15.8 kg 34.8 lb
Product Net Depth / Length
235 mm 9.25 in
Product Net Height
658 mm 25.91 in
Product Net Width
165 mm 6.50 in
Package Level 1 Depth / Length
700 mm 27.56 in
Package Level 1 Height
360 mm 14.17 in
Package Level 1 Width
260 mm 10.24 in
Package Level 1 Units
1 carton
Number of Phases
3
Degree of Protection
IP20
Enclosure Type NEMA
Open Type
Altitude
1000 m
Operating Humidity (RH<span style="font-size:x-small;">amb</span>)
5 ... 95
Power Factor
0.98
Sound dB (A)
71 dB(A)
Multiple Battery Information
Lithium Coin, CR2032, 220 mAh, 3 V, 2 pcs, 6 g
Frequency (f)
47.5 ... 63 Hz
Frame Size
R3
Input Voltage (Uin)
380 ... 500 V
Mounting Type
Module
Communication Protocol
CAN DeviceNet EtherNet/IP MODBUS Other Bus Systems PROFIsafe PROFIBUS PROFINET IO TCP/IP
Number of Hardware Interfaces
Industrial Ethernet 0 Other 3 Parallel 0 PROFINET 0 RS-232 0 RS-422 0 RS-485 1 Serial TTY 0 USB 0
Includes
PC connection
Analog Inputs
2
Analog Outputs
2
Number of Digital In/Outputs
6 / 5
Output Current, Heavy-Duty Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">IHD</span>)
35 A
Output Current, Light-Overload Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">ILD</span>)
41 A
Output Current, Normal Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">In</span>)
44 A
Output Power, Heavy-Duty Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">PHD</span>)
18.5 kW
Output Power, Light-Overload Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">PLD</span>)
22 kW
Output Power, Normal Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">Pn</span>)
22 kW
Apparent Power Output
30 kV·A
Efficiency Level
IE2
Standby Loss
34 W
Temperature Rating
Maximum 40 °C
Output Current, Heavy-Duty Use (UL)
35 A
Output Current, Light-Overload Use (UL)
41 A
Output Power, Heavy-Duty Use (UL)
25 Hp
Output Power, Light-Overload Use (UL)
30 Hp
UNSPSC
39122001
SCIP
056afa37-4c9d-45a8-b6fa-8011be013b84 Finland (FI)
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Product Name
Frequency converter
Manufacturer ID
3AXD50000036411