Product Model
AF205B-30-22-13

Selling Points
- 1Controls motors up to 110 kW / 400 V AC or 150 hp / 480 V UL.
- 2Switches power circuits up to 350 A (AC-1) or 300 A UL general use.
- 3Wide control voltage range of 100-250 V 50/60 Hz and DC.
- 4Built-in surge protection for reliable operation in unstable networks.
- 5Compact block type design with easy extension options for auxiliary contacts.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 105 mm | Product Net Depth / Length | 152 mm |
Product Net Height | 196 mm | Product Net Weight | 2.4 kg |
Number of Main Contacts NO | 3 | Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 2 | Number of Auxiliary Contacts NC | 2 |
Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. | Rated Operational Voltage | Main Circuit 1000 V |
Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 275 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 60 °C 300 A (690 V) 70 °C 240 A | Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 205 A (440 V) 55 °C 205 A (500 V) 55 °C 165 A (690 V) 55 °C 165 A (1000 V) 55 °C 100 A (380 / 400 V) 55 °C 205 A (220 / 230 / 240 V) 55 °C 205 A |
Rated Operational Power AC-3 (Pe) | (415 V) 110 kW (440 V) 132 kW (500 V) 110 kW (690 V) 160 kW (1000 V) 132 kW (380 / 400 V) 110 kW (220 / 230 / 240 V) 55 kW | Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A |
Rated Operational Current DC-1 (Ie) | (100 V) 1 Pole, 40 °C 350 A (100 V) 1 Pole, 60 °C 300 A (100 V) 1 Pole, 70 °C 240 A (110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 300 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 300 A (110 V) 3 Poles in Series, 70 °C 240 A (175 V) 2 Poles in Series, 40 °C 350 A (175 V) 2 Poles in Series, 60 °C 300 A (175 V) 2 Poles in Series, 70 °C 240 A (200 V) 2 Poles in Series, 40 °C 350 A (200 V) 2 Poles in Series, 60 °C 300 A (200 V) 2 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 300 A (220 V) 3 Poles in Series, 70 °C 240 A (260 V) 3 Poles in Series, 40 °C 350 A (260 V) 3 Poles in Series, 60 °C 300 A (260 V) 3 Poles in Series, 70 °C 240 A (300 V) 3 Poles in Series, 40 °C 350 A (300 V) 3 Poles in Series, 60 °C 300 A (300 V) 3 Poles in Series, 70 °C 240 A (72 V) 1-Pole, 40 °C 350 A (72 V) 1-Pole, 60 °C 300 A (72 V) 1-Pole, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 300 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 300 A (72 V) 3 Poles in Series, 70 °C 240 A (90 V) 1 Pole, 40 °C 350 A (90 V) 1 Pole, 60 °C 300 A (90 V) 1 Pole, 70 °C 240 A | Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A (110 V) 2 Poles in Series, 60 °C 275 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 275 A (110 V) 3 Poles in Series, 60 °C 275 A (110 V) 3 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 60 °C 275 A (220 V) 3 Poles in Series, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 275 A (72 V) 2 Poles in Series, 60 °C 275 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 275 A (72 V) 3 Poles in Series, 60 °C 275 A (72 V) 3 Poles in Series, 70 °C 240 A |
Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A (110 V) 2 Poles in Series, 60 °C 275 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 275 A (110 V) 3 Poles in Series, 60 °C 275 A (110 V) 3 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 60 °C 275 A (220 V) 3 Poles in Series, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 275 A (72 V) 2 Poles in Series, 60 °C 275 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 275 A (72 V) 3 Poles in Series, 60 °C 275 A (72 V) 3 Poles in Series, 70 °C 240 A | Mechanical Durability | 5 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour | Rated Control Circuit Voltage (Uc) | 50 Hz / 60 Hz 100 ... 250 V DC Operation 100 ... 250 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage DC 190 W | Terminal Type | Main Circuit: Bars |
General Use Rating UL/CSA | (600 V AC) 300 A | Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 60 hp (220 ... 240 V AC) Three Phase 75 hp (440 ... 480 V AC) Three Phase 150 hp (550 ... 600 V AC) Three Phase 200 hp |
Object Classification Code | Q | ETIM 7 | EC000066 - Power contactor, AC switching |
ETIM 8 | EC000066 - Power contactor, AC switching | ETIM 9 | EC000066 - Power contactor, AC switching |
eClass | V11.0 : 27371003 | UNSPSC | 39121529 |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors | E-Number (Sweden) | 3210446 |
Manufacturer ID | 1SFL527063R1322 |
Specifications may be subject to change without notice