Product Model

AF205B-30-22-13

In Stock
Last updated: 2025/4/18
ABB AF205B-30-22-13

Selling Points

  • 1Controls motors up to 110 kW / 400 V AC or 150 hp / 480 V UL.
  • 2Switches power circuits up to 350 A (AC-1) or 300 A UL general use.
  • 3Wide control voltage range of 100-250 V 50/60 Hz and DC.
  • 4Built-in surge protection for reliable operation in unstable networks.
  • 5Compact block type design with easy extension options for auxiliary contacts.
Product Details
AF205B-30-22-13
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
105 mm
Product Net Depth / Length
152 mm
Product Net Height
196 mm
Product Net Weight
2.4 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 275 A (1000 V) 60 °C 250 A (1000 V) 70 °C 200 A (690 V) 40 °C 350 A (690 V) 60 °C 300 A (690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 205 A (440 V) 55 °C 205 A (500 V) 55 °C 165 A (690 V) 55 °C 165 A (1000 V) 55 °C 100 A (380 / 400 V) 55 °C 205 A (220 / 230 / 240 V) 55 °C 205 A
Rated Operational Power AC-3 (Pe)
(415 V) 110 kW (440 V) 132 kW (500 V) 110 kW (690 V) 160 kW (1000 V) 132 kW (380 / 400 V) 110 kW (220 / 230 / 240 V) 55 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 350 A (100 V) 1 Pole, 60 °C 300 A (100 V) 1 Pole, 70 °C 240 A (110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 300 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 300 A (110 V) 3 Poles in Series, 70 °C 240 A (175 V) 2 Poles in Series, 40 °C 350 A (175 V) 2 Poles in Series, 60 °C 300 A (175 V) 2 Poles in Series, 70 °C 240 A (200 V) 2 Poles in Series, 40 °C 350 A (200 V) 2 Poles in Series, 60 °C 300 A (200 V) 2 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 300 A (220 V) 3 Poles in Series, 70 °C 240 A (260 V) 3 Poles in Series, 40 °C 350 A (260 V) 3 Poles in Series, 60 °C 300 A (260 V) 3 Poles in Series, 70 °C 240 A (300 V) 3 Poles in Series, 40 °C 350 A (300 V) 3 Poles in Series, 60 °C 300 A (300 V) 3 Poles in Series, 70 °C 240 A (72 V) 1-Pole, 40 °C 350 A (72 V) 1-Pole, 60 °C 300 A (72 V) 1-Pole, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 300 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 300 A (72 V) 3 Poles in Series, 70 °C 240 A (90 V) 1 Pole, 40 °C 350 A (90 V) 1 Pole, 60 °C 300 A (90 V) 1 Pole, 70 °C 240 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A (110 V) 2 Poles in Series, 60 °C 275 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 275 A (110 V) 3 Poles in Series, 60 °C 275 A (110 V) 3 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 60 °C 275 A (220 V) 3 Poles in Series, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 275 A (72 V) 2 Poles in Series, 60 °C 275 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 275 A (72 V) 3 Poles in Series, 60 °C 275 A (72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 275 A (110 V) 2 Poles in Series, 60 °C 275 A (110 V) 2 Poles in Series, 70 °C 240 A (110 V) 3 Poles in Series, 40 °C 275 A (110 V) 3 Poles in Series, 60 °C 275 A (110 V) 3 Poles in Series, 70 °C 240 A (220 V) 3 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 60 °C 275 A (220 V) 3 Poles in Series, 70 °C 240 A (72 V) 2 Poles in Series, 40 °C 275 A (72 V) 2 Poles in Series, 60 °C 275 A (72 V) 2 Poles in Series, 70 °C 240 A (72 V) 3 Poles in Series, 40 °C 275 A (72 V) 3 Poles in Series, 60 °C 275 A (72 V) 3 Poles in Series, 70 °C 240 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A Pull-in at Max. Rated Control Circuit Voltage DC 190 W
Terminal Type
Main Circuit: Bars
General Use Rating UL/CSA
(600 V AC) 300 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 60 hp (220 ... 240 V AC) Three Phase 75 hp (440 ... 480 V AC) Three Phase 150 hp (550 ... 600 V AC) Three Phase 200 hp
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210446
Manufacturer ID
1SFL527063R1322

Specifications may be subject to change without notice