Product Model

AF265B-30-22-11

In Stock
Last updated: 2025/4/24
ABB AF265B-30-22-11

Selling Points

  • 1High operational currents up to 132 kW / 400 V AC or 200 hp / 480 V UL.
  • 2Built-in surge protection for reliable operation in unstable networks.
  • 3Compact design with pre-mounted auxiliary contacts and ring tongue ferrules.
  • 4Wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC).
  • 5Meets IEC, UL, and CSA standards for compliance in various applications.
Product Details
AF265B-30-22-11
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 350 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 60 °C 350 A (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 265 A (440 V) 55 °C 265 A (500 V) 55 °C 250 A (690 V) 55 °C 250 A (1000 V) 55 °C 100 A (380 / 400 V) 55 °C 265 A (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe)
(415 V) 132 kW (440 V) 160 kW (500 V) 200 kW (690 V) 200 kW (1000 V) 160 kW (380 / 400 V) 132 kW (220 / 230 / 240 V) 75 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 400 A (100 V) 1 Pole, 60 °C 350 A (100 V) 1 Pole, 70 °C 290 A (110 V) 1-Pole, 40 °C 400 A (110 V) 1-Pole, 60 °C 350 A (110 V) 1-Pole, 70 °C 290 A (110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (175 V) 2 Poles in Series, 40 °C 400 A (175 V) 2 Poles in Series, 60 °C 350 A (175 V) 2 Poles in Series, 70 °C 290 A (200 V) 2 Poles in Series, 40 °C 400 A (200 V) 2 Poles in Series, 60 °C 350 A (200 V) 2 Poles in Series, 70 °C 290 A (220 V) 2 Poles in Series, 40 °C 400 A (220 V) 2 Poles in Series, 60 °C 350 A (220 V) 2 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (260 V) 3 Poles in Series, 40 °C 400 A (260 V) 3 Poles in Series, 60 °C 350 A (260 V) 3 Poles in Series, 70 °C 290 A (300 V) 3 Poles in Series, 40 °C 400 A (300 V) 3 Poles in Series, 60 °C 350 A (300 V) 3 Poles in Series, 70 °C 290 A (340 V) 3 Poles in Series, 40 °C 400 A (340 V) 3 Poles in Series, 60 °C 350 A (340 V) 3 Poles in Series, 70 °C 290 A (72 V) 1-Pole, 40 °C 400 A (72 V) 1-Pole, 60 °C 350 A (72 V) 1-Pole, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A (90 V) 1 Pole, 40 °C 400 A (90 V) 1 Pole, 60 °C 350 A (90 V) 1 Pole, 70 °C 290 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 350 A (110 V) 2 Poles in Series, 60 °C 350 A (110 V) 2 Poles in Series, 70 °C 290 A (110 V) 3 Poles in Series, 40 °C 350 A (110 V) 3 Poles in Series, 60 °C 350 A (110 V) 3 Poles in Series, 70 °C 290 A (220 V) 3 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 60 °C 350 A (220 V) 3 Poles in Series, 70 °C 290 A (72 V) 2 Poles in Series, 40 °C 350 A (72 V) 2 Poles in Series, 60 °C 350 A (72 V) 2 Poles in Series, 70 °C 290 A (72 V) 3 Poles in Series, 40 °C 350 A (72 V) 3 Poles in Series, 60 °C 350 A (72 V) 3 Poles in Series, 70 °C 290 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Terminal Type
Main Circuit: Bars
NEMA Size
5
Continuous Current Rating NEMA
270 A
Horsepower Rating NEMA
(200 V AC) Three Phase 75 Hp (230 V AC) Three Phase 100 Hp (460 V AC) Three Phase 200 Hp (575 V AC) Three Phase 200 Hp
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 75 hp (220 ... 240 V AC) Three Phase 100 hp (440 ... 480 V AC) Three Phase 200 hp (550 ... 600 V AC) Three Phase 250 hp
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210448
Manufacturer ID
1SFL547063R1122

Specifications may be subject to change without notice