Product Model

AF305B-40-22-13

In Stock
Last updated: 2025/4/21
ABB AF305B-40-22-13

Selling Points

  • 1High reliability and long service life.
  • 2Compact design for easy installation.
  • 3Switches electric motors and other AC loads efficiently.
  • 4Meets international safety standards (IEC 60529, IEC 60947-1).
  • 5Suitable for a wide range of operating voltages (100-250V AC).
Product Details
AF305B-40-22-13
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 375 A (1000 V) 60 °C 325 A (1000 V) 70 °C 260 A (690 V) 40 °C 500 A (690 V) 60 °C 400 A (690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 305 A (440 V) 55 °C 305 A (380 / 400 V) 55 °C 305 A (220 / 230 / 240 V) 55 °C 305 A
Rated Operational Power AC-3 (Pe)
(415 V) 160 kW (440 V) 160 kW (500 V) 200 kW (690 V) 250 kW (1000 V) 185 kW (380 / 400 V) 160 kW (220 / 230 / 240 V) 90 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 500 A (100 V) 1 Pole, 60 °C 400 A (100 V) 1 Pole, 70 °C 325 A (110 V) 1-Pole, 40 °C 500 A (110 V) 1-Pole, 60 °C 400 A (110 V) 1-Pole, 70 °C 325 A (110 V) 2 Poles in Series, 40 °C 500 A (110 V) 2 Poles in Series, 60 °C 400 A (110 V) 2 Poles in Series, 70 °C 325 A (110 V) 3 Poles in Series, 40 °C 500 A (110 V) 3 Poles in Series, 60 °C 400 A (110 V) 3 Poles in Series, 70 °C 325 A (175 V) 2 Poles in Series, 40 °C 500 A (175 V) 2 Poles in Series, 60 °C 400 A (175 V) 2 Poles in Series, 70 °C 325 A (200 V) 2 Poles in Series, 40 °C 500 A (200 V) 2 Poles in Series, 60 °C 400 A (200 V) 2 Poles in Series, 70 °C 325 A (220 V) 2 Poles in Series, 40 °C 500 A (220 V) 2 Poles in Series, 60 °C 400 A (220 V) 2 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 500 A (220 V) 3 Poles in Series, 60 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (260 V) 3 Poles in Series, 40 °C 500 A (260 V) 3 Poles in Series, 60 °C 400 A (260 V) 3 Poles in Series, 70 °C 325 A (300 V) 3 Poles in Series, 40 °C 500 A (300 V) 3 Poles in Series, 60 °C 400 A (300 V) 3 Poles in Series, 70 °C 325 A (340 V) 3 Poles in Series, 40 °C 500 A (340 V) 3 Poles in Series, 60 °C 400 A (340 V) 3 Poles in Series, 70 °C 325 A (350 V) 4 Poles in Series, 40 °C 500 A (350 V) 4 Poles in Series, 60 °C 400 A (350 V) 4 Poles in Series, 70 °C 325 A (400 V) 4 Poles in Series, 40 °C 500 A (400 V) 4 Poles in Series, 60 °C 400 A (400 V) 4 Poles in Series, 70 °C 325 A (440 V) 4 Poles in Series, 40 °C 500 A (440 V) 4 Poles in Series, 60 °C 400 A (440 V) 4 Poles in Series, 70 °C 325 A (72 V) 1-Pole, 40 °C 500 A (72 V) 1-Pole, 60 °C 400 A (72 V) 1-Pole, 70 °C 325 A (72 V) 2 Poles in Series, 40 °C 500 A (72 V) 2 Poles in Series, 60 °C 400 A (72 V) 2 Poles in Series, 70 °C 325 A (72 V) 3 Poles in Series, 40 °C 500 A (72 V) 3 Poles in Series, 60 °C 400 A (72 V) 3 Poles in Series, 70 °C 325 A (90 V) 1 Pole, 40 °C 500 A (90 V) 1 Pole, 60 °C 400 A (90 V) 1 Pole, 70 °C 325 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 400 A (110 V) 2 Poles in Series, 70 °C 325 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 400 A (110 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 400 A (72 V) 2 Poles in Series, 70 °C 325 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 400 A (72 V) 3 Poles in Series, 70 °C 325 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 400 A (110 V) 2 Poles in Series, 60 °C 400 A (110 V) 2 Poles in Series, 70 °C 325 A (110 V) 3 Poles in Series, 40 °C 400 A (110 V) 3 Poles in Series, 60 °C 400 A (110 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 400 A (220 V) 3 Poles in Series, 60 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (72 V) 2 Poles in Series, 40 °C 400 A (72 V) 2 Poles in Series, 60 °C 400 A (72 V) 2 Poles in Series, 70 °C 325 A (72 V) 3 Poles in Series, 40 °C 400 A (72 V) 3 Poles in Series, 60 °C 400 A (72 V) 3 Poles in Series, 70 °C 325 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Terminal Type
Main Circuit: Bars
General Use Rating UL/CSA
(600 V AC) 350 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 40 Hp (200 V AC) Three Phase 100 hp (208 V AC) Three Phase 100 hp (220 ... 240 V AC) Three Phase 50 Hp (220 ... 240 V AC) Three Phase 125 hp (440 ... 480 V AC) Three Phase 100 Hp (440 ... 480 V AC) Three Phase 250 hp (550 ... 600 V AC) Three Phase 150 Hp (550 ... 600 V AC) Three Phase 300 hp
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210482
Manufacturer ID
1SFL587263R1322

Specifications may be subject to change without notice