Product Model

AF370B-40-22-13

In Stock
Last updated: 2025/4/23
ABB AF370B-40-22-13

Selling Points

  • 1Supports up to 1000 V IEC or 600 V UL.
  • 2Handles 525 A (AC-1) or 420 A UL general use.
  • 3Ensures reliable operation in unstable networks.
  • 4Block type design with add-on auxiliary contact blocks.
  • 5Operates from 250 to 500 V DC or AC.
Product Details
AF370B-40-22-13
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A (1000 V) 60 °C 350 A (1000 V) 70 °C 290 A (690 V) 40 °C 525 A (690 V) 60 °C 425 A (690 V) 70 °C 350 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 370 A (440 V) 55 °C 370 A (380 / 400 V) 55 °C 370 A (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW (440 V) 200 kW (500 V) 250 kW (690 V) 315 kW (1000 V) 200 kW (380 / 400 V) 200 kW (220 / 230 / 240 V) 110 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 520 A (100 V) 1 Pole, 60 °C 425 A (100 V) 1 Pole, 70 °C 350 A (110 V) 1-Pole, 40 °C 520 A (110 V) 1-Pole, 60 °C 425 A (110 V) 1-Pole, 70 °C 350 A (110 V) 2 Poles in Series, 40 °C 520 A (110 V) 2 Poles in Series, 60 °C 425 A (110 V) 2 Poles in Series, 70 °C 350 A (110 V) 3 Poles in Series, 40 °C 520 A (110 V) 3 Poles in Series, 60 °C 425 A (110 V) 3 Poles in Series, 70 °C 350 A (175 V) 2 Poles in Series, 40 °C 520 A (175 V) 2 Poles in Series, 60 °C 425 A (175 V) 2 Poles in Series, 70 °C 350 A (200 V) 2 Poles in Series, 40 °C 520 A (200 V) 2 Poles in Series, 60 °C 425 A (200 V) 2 Poles in Series, 70 °C 350 A (220 V) 2 Poles in Series, 40 °C 520 A (220 V) 2 Poles in Series, 60 °C 425 A (220 V) 2 Poles in Series, 70 °C 350 A (220 V) 3 Poles in Series, 40 °C 520 A (220 V) 3 Poles in Series, 60 °C 425 A (220 V) 3 Poles in Series, 70 °C 350 A (260 V) 3 Poles in Series, 40 °C 520 A (260 V) 3 Poles in Series, 60 °C 425 A (260 V) 3 Poles in Series, 70 °C 350 A (300 V) 3 Poles in Series, 40 °C 520 A (300 V) 3 Poles in Series, 60 °C 425 A (300 V) 3 Poles in Series, 70 °C 350 A (340 V) 3 Poles in Series, 40 °C 520 A (340 V) 3 Poles in Series, 60 °C 425 A (340 V) 3 Poles in Series, 70 °C 350 A (350 V) 4 Poles in Series, 40 °C 520 A (350 V) 4 Poles in Series, 60 °C 425 A (350 V) 4 Poles in Series, 70 °C 350 A (400 V) 4 Poles in Series, 40 °C 520 A (400 V) 4 Poles in Series, 60 °C 425 A (400 V) 4 Poles in Series, 70 °C 350 A (440 V) 4 Poles in Series, 40 °C 520 A (440 V) 4 Poles in Series, 60 °C 425 A (440 V) 4 Poles in Series, 70 °C 350 A (72 V) 1-Pole, 40 °C 520 A (72 V) 1-Pole, 60 °C 425 A (72 V) 1-Pole, 70 °C 350 A (72 V) 2 Poles in Series, 40 °C 520 A (72 V) 2 Poles in Series, 60 °C 425 A (72 V) 2 Poles in Series, 70 °C 350 A (72 V) 3 Poles in Series, 40 °C 520 A (72 V) 3 Poles in Series, 60 °C 425 A (72 V) 3 Poles in Series, 70 °C 350 A (90 V) 1 Pole, 40 °C 520 A (90 V) 1 Pole, 60 °C 425 A (90 V) 1 Pole, 70 °C 350 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A (110 V) 2 Poles in Series, 60 °C 425 A (110 V) 2 Poles in Series, 70 °C 350 A (110 V) 3 Poles in Series, 40 °C 450 A (110 V) 3 Poles in Series, 60 °C 425 A (110 V) 3 Poles in Series, 70 °C 350 A (220 V) 3 Poles in Series, 40 °C 450 A (220 V) 3 Poles in Series, 60 °C 425 A (220 V) 3 Poles in Series, 70 °C 350 A (72 V) 2 Poles in Series, 40 °C 450 A (72 V) 2 Poles in Series, 60 °C 425 A (72 V) 2 Poles in Series, 70 °C 350 A (72 V) 3 Poles in Series, 40 °C 450 A (72 V) 3 Poles in Series, 60 °C 425 A (72 V) 3 Poles in Series, 70 °C 350 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A (110 V) 2 Poles in Series, 60 °C 425 A (110 V) 2 Poles in Series, 70 °C 350 A (110 V) 3 Poles in Series, 40 °C 450 A (110 V) 3 Poles in Series, 60 °C 425 A (110 V) 3 Poles in Series, 70 °C 350 A (220 V) 3 Poles in Series, 40 °C 450 A (220 V) 3 Poles in Series, 60 °C 425 A (220 V) 3 Poles in Series, 70 °C 350 A (72 V) 2 Poles in Series, 40 °C 450 A (72 V) 2 Poles in Series, 60 °C 425 A (72 V) 2 Poles in Series, 70 °C 350 A (72 V) 3 Poles in Series, 40 °C 450 A (72 V) 3 Poles in Series, 60 °C 425 A (72 V) 3 Poles in Series, 70 °C 350 A
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Terminal Type
Main Circuit: Bars
General Use Rating UL/CSA
(600 V AC) 420 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 50 Hp (200 V AC) Three Phase 125 hp (208 V AC) Three Phase 125 hp (220 ... 240 V AC) Three Phase 60 Hp (220 ... 240 V AC) Three Phase 150 hp (440 ... 480 V AC) Three Phase 125 Hp (440 ... 480 V AC) Three Phase 300 hp (550 ... 600 V AC) Three Phase 150 Hp (550 ... 600 V AC) Three Phase 350 hp
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210486
Manufacturer ID
1SFL607263R1322

Specifications may be subject to change without notice