Product Model
AF400-30-22 100-250V

Selling Points
- 1Operates on 100-250V AC/DC, ensuring flexibility in various industrial settings.
- 2Handles up to 400A (AC-3) and 550A (UL/CSA general use), supporting heavy-duty applications.
- 3Built with a block type design, offering easy extension with add-on auxiliary contact blocks and accessories.
- 4Integrated surge protection ensures reliable operation in unstable networks, reducing panel energy consumption.
- 5Compact dimensions (186mm x 216mm x 278mm) make it ideal for space-constrained installations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 186 mm | Product Net Depth / Length | 216 mm |
Product Net Height | 278 mm | Product Net Weight | 10.6 kg |
Number of Main Contacts NO | 3 | Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 2 | Number of Auxiliary Contacts NC | 2 |
Rated Operational Voltage | Main Circuit 1000 V | Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 600 A (1000 V) 55 °C 500 A (1000 V) 70 °C 400 A (690 V) 40 °C 600 A (690 V) 55 °C 500 A (690 V) 60 °C 500 A (690 V) 70 °C 400 A |
Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 400 A (440 V) 55 °C 400 A (500 V) 55 °C 400 A (690 V) 55 °C 350 A (1000 V) 55 °C 155 A (380 / 400 V) 55 °C 400 A (220 / 230 / 240 V) 55 °C 400 A | Rated Operational Power AC-3 (Pe) | (415 V) 220 kW (440 V) 220 kW (500 V) 250 kW (690 V) 315 kW (1000 V) 220 kW (380 / 400 V) 200 kW (220 / 230 / 240 V) 110 kW |
Mechanical Durability | 3 million | Maximum Mechanical Switching Frequency | 300 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz / 60 Hz 100 ... 250 V DC Operation 100 ... 250 V | Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 955 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 955 V·A Pull-in at Max. Rated Control Circuit Voltage DC 895 V·A |
Terminal Type | Main Circuit: Bars | Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 125 Hp (220 ... 240 V AC) Three Phase 150 Hp (440 ... 480 V AC) Three Phase 350 Hp (550 ... 600 V AC) Three Phase 400 Hp | Object Classification Code | Q |
ETIM 7 | EC000066 - Power contactor, AC switching | ETIM 8 | EC000066 - Power contactor, AC switching |
ETIM 9 | EC000066 - Power contactor, AC switching | eClass | V11.0 : 27371003 |
UNSPSC | 39121529 | IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Manufacturer ID | 1SFL577001R9106 |