Product Model
AF580-30-22 100-250V

Selling Points
- 1High Power Rating: Handles up to 315 kW, 500 hp, and 600 hp.
- 2Versatile Voltage Control: Operates with a wide control voltage range of 100 to 250 VAC/VDC.
- 3Durable Design: Withstands short voltage dips and sags, ensuring reliable operation.
- 4Built-in Surge Suppression: Protects against electrical surges for added reliability.
- 5Compact and Efficient: Reduces panel energy consumption with its compact design.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 210 mm | Product Net Depth / Length | 242 mm |
Product Net Height | 283 mm | Product Net Weight | 13.6 kg |
Number of Main Contacts NO | 3 | Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 2 | Number of Auxiliary Contacts NC | 2 |
Rated Operational Voltage | Main Circuit 1000 V | Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 800 A (1000 V) 55 °C 700 A (1000 V) 70 °C 580 A (690 V) 40 °C 800 A (690 V) 55 °C 700 A (690 V) 70 °C 580 A |
Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 580 A (440 V) 55 °C 580 A (500 V) 55 °C 580 A (690 V) 55 °C 500 A (1000 V) 55 °C 250 A (380 / 400 V) 55 °C 580 A (220 / 230 / 240 V) 55 °C 580 A | Rated Operational Power AC-3 (Pe) | (415 V) 355 kW (440 V) 355 kW (500 V) 400 kW (690 V) 500 kW (1000 V) 355 kW (380 / 400 V) 315 kW (220 / 230 / 240 V) 160 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A | Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V |
Mechanical Durability | 3 million | Maximum Mechanical Switching Frequency | 300 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V | Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A |
Terminal Type | Main Circuit: Bars | Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 200 Hp (220 ... 240 V AC) Three Phase 250 Hp (440 ... 480 V AC) Three Phase 500 Hp (550 ... 600 V AC) Three Phase 600 Hp | Object Classification Code | Q |
ETIM 7 | EC000066 - Power contactor, AC switching | ETIM 8 | EC000066 - Power contactor, AC switching |
ETIM 9 | EC000066 - Power contactor, AC switching | eClass | V11.0 : 27371003 |
UNSPSC | 39121529 | IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Manufacturer ID | 1SFL617001R9105 |
Specifications may be subject to change without notice