Product Model
AX205-30-11-88

Selling Points
- 1Reliable Motor Control: The AX205-30-11-88 contactor is designed for controlling 3-phase motors and power circuits up to 690V AC, ensuring reliable operation in industrial settings.
- 2High Current Capacity: With a rated operational current of 205A at 415V AC-3, this contactor can handle demanding applications with ease.
- 3Compact Design: The contactor features a compact design with dimensions of 111.5 mm x 162.3 mm x 196 mm, making it ideal for space-saving installations.
- 4Easy Installation: The terminals are delivered in open position, allowing for faster wiring and easier installation, reducing project timelines.
- 5Comprehensive Accessories: The AX205-30-11-88 comes with a wide range of accessories including auxiliary contact blocks for front or side mounting, enhancing flexibility and performance in motor starting applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 111.5 mm | Product Net Depth / Length | 162.3 mm |
Product Net Height | 196 mm | Product Net Weight | 3.2 kg |
Number of Main Contacts NO | 3 | Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 | Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V | Rated Frequency (f) | Main Circuit 50 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Π= 40 °C 250 A | Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 275 A (690 V) 55 °C 250 A (690 V) 70 °C 180 A |
Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 205 A (440 V) 55 °C 185 A (500 V) 55 °C 170 A (690 V) 55 °C 170 A (380 / 400 V) 55 °C 205 A (220 / 230 / 240 V) 55 °C 205 A | Rated Operational Power AC-3 (Pe) | (415 V) 110 kW (440 V) 90 kW (500 V) 110 kW (690 V) 132 kW (380 / 400 V) 110 kW (220 / 230 / 240 V) 59 kW |
Rated Breaking Capacity AC-3 | 8 x Ie AC-3 | Rated Making Capacity AC-3 | 10 x Ie AC-3 |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A | Maximum Electrical Switching Frequency | 300 cycles per hour |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Mechanical Durability | 5 million | Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) Uc (at θ ⤠70 °C) | Rated Control Circuit Voltage (Uc) | 50 Hz 230 ... 240 V 60 Hz 240 ... 260 V |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 | Terminal Type | Main Circuit: Bars |
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C | Maximum Operating Altitude Permissible | Without Derating 3000 m |
Object Classification Code | Q | ETIM 7 | EC000066 - Power contactor, AC switching |
ETIM 8 | EC000066 - Power contactor, AC switching | ETIM 9 | EC000066 - Power contactor, AC switching |
eClass | V11.0 : 27371003 | UNSPSC | 39121529 |
IDEA Granular Category Code (IGCC) | 4755 >> Contactors | Manufacturer ID | 1SFL501074R8811 |
Specifications may be subject to change without notice