Product Model
BC6-40-00-05

Selling Points
- 1Compact design for space-saving installations.
- 2Reliable performance in residential, commercial, and industrial settings.
- 3Versatile connectivity options with screw terminals.
- 4Suitable for control of single or three-phase loads up to 4 kW (AC-3).
- 5Integrated switch position indication and rail or wall mounting capabilities.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 52.5 mm | Product Net Height | 57.5 mm |
Product Net Depth / Length | 46.7 mm | Product Net Weight | 0.175 kg |
Number of Poles | 4 | Mini Contactor Type | Mini Contactor |
Rated Operational Voltage | Main Circuit 690 V AC Main Circuit 220 V DC | Rated Frequency (f) | Control Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz Main Circuit DC |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV | Rated Insulation Voltage (Ui) | 690 V acc. to UL/CSA 600 V |
Number of Main Contacts NC | 0 | Number of Main Contacts NO | 4 |
Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 A (220 / 240 V) 55 °C 16 A (380 / 440 V) 40 °C 20 A (380 / 440 V) 55 °C 16 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A | Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NO 3 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A | Number of Auxiliary Contacts NC | 0 |
Number of Auxiliary Contacts NO | 0 | Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
Rated Control Circuit Voltage (Uc) | 220 ... 240 V DC | Coil Operating Limits | (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ⤠55 °C) |
Degree of Protection | Control Circuit Terminals IP20 Main Circuit Terminals IP20 | Mechanical Durability | 10000000 cycle |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-3) 600 cycles per hour | Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² | Wire Stripping Length | Main Circuit 9 mm |
Tightening Torque | Control Circuit 0.8 ... 1.1 N·m Main Circuit 0.8 ... 1.1 N·m | Recommended Screw Driver | M3 Pozidriv 1 |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L | Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Full Load Amps Motor Use | (115 V AC) Single Phase 5.8 A (200 V AC) Three Phase 4.8 A (220 ... 240 V AC) Three Phase 6.8 A (230 V AC) Single Phase 4.9 A (440 ... 480 V AC) Three Phase 4.8 A (550 ... 600 V AC) Three Phase 1.7 A | Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.25 Hp (200 V AC) Three Phase 1 Hp (220 ... 240 V AC) Three Phase 2 Hp (230 V AC) Single Phase 0.5 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 1 Hp |
General Use Rating UL/CSA | (300 V AC) 12 A | Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 22-10 AWG |
Tightening Torque UL/CSA | Control Circuit 7 in·lb Main Circuit 7 in·lb | Ambient Air Temperature | Operation -20 ... +55 °C Storage -40 ... +80 °C |
Maximum Operating Altitude Permissible | 2000 m | Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
Resistance to Vibrations | 5g 5 ... 150 Hz | Object Classification Code | Q |
ETIM 4 | EC000066 - Magnet contactor, AC-switching | ETIM 5 | EC000066 - Magnet contactor, AC-switching |
ETIM 6 | EC000066 - Power contactor, AC switching | ETIM 7 | EC000066 - Power contactor, AC switching |
ETIM 8 | EC000066 - Power contactor, AC switching | eClass | V11.0 : 27371003 |
UNSPSC | 39121529 | Manufacturer ID | GJL1213201R0005 |
Specifications may be subject to change without notice