Product Model

CM-ESS.MS

In Stock
Last updated: 2025/4/20
ABB CM-ESS.MS

Selling Points

  • 1Multi-Range Voltage Monitoring: Measures DC and AC voltages with 4 ranges: 3-30 V, 6-60 V, 30-300 V, and 60-600 V.
  • 2Adjustable Tripping Delay: Tripping delay adjustable from instantaneous to 30 seconds for precise control.
  • 3Versatile Operating Principle: Selectable over- or undervoltage monitoring with open- or closed-circuit operating principles.
  • 4High Insulation and Protection: Rated insulation voltage up to 600 V and meets UL 94 V-0 fire protection standards.
  • 5Durable and Reliable: Designed for high mechanical durability with a cycle count of 30 million and electrical durability of 100,000 cycles.
Product Details
CM-ESS.MS
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
22.5 mm
Product Net Height
85.6 mm
Product Net Depth / Length
103.7 mm
Product Net Weight
0.154 kg
Function
Over- or undervoltage monitoring
Measuring Range
3 ... 30 V 6 ... 60 V 30 ... 300 V 60 ... 600 V
Time Range
0 s or 0.1 ... 30 s tripping delay (ON)
Rated Control Supply Voltage (Us)
24 ... 240 V AC/DC
Output
2 c/o (SPDT) contact; operating principle selectable
Terminal Type
Screw Terminals
Rated Operational Current AC-12 (Ie)
(230 V) 4 A
Rated Operational Current AC-15 (Ie)
(230 V) 3 A
Rated Operational Current DC-12 (Ie)
(24 V) 4 A
Rated Operational Current DC-13 (Ie)
(24 V) 2 A
Minimum Switching Capacity
24 V 10 mA
Rated Impulse Withstand Voltage (Uimp)
Measuring Circuit / Output Circuit 6 kV Output Circuit 1 / Output Circuit 2 4 kV Supply Circuit / Measuring Circuit 6 kV Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui)
Measuring Circuit / Output Circuit 600 V Output Circuit 1 / Output Circuit 2 250 V Supply Circuit / Measuring Circuit 600 V Supply Circuit / Output Circuit 250 V
Degree of Protection
Housing IP50 Terminals IP20
Overvoltage Category
III
Pollution Degree
3
Short-Circuit Protective Devices
Output Circuit NC - F Type Fuses 10 A Output Circuit NO - F Type Fuses 10 A
Electrical Durability
AC-12 100000 cycle
Mechanical Durability
30000000 cycle
Connecting Capacity
Flexible with Ferrule 1x 0.5 ... 2.5 mm² Flexible with Ferrule 2x 0.5 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² Flexible 1x 0.5 ... 2.5 mm² Flexible 2x 0.5 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque
0.6 ... 0.8 N·m
Wire Stripping Length
8 mm
Recommended Screw Driver
0.8 x 4 4.5 Pozidriv 1
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards
CAN/CSA C22.2 No.14 IEC/EN 63000 IEC/EN 60255-27 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508
Maximum Operating Voltage UL/CSA
Output Circuit 300 V AC
Contact Rating UL/CSA
B300
Connecting Capacity UL/CSA
Flexible 1x 18-14 AWG Flexible 2x 18-16 AWG Rigid 1x 20-12 AWG Rigid 2x 20-14 AWG
Tightening Torque UL/CSA
7.08 in·lb
Pilot Duty UL/CSA
B300
Flammability According to UL94
V-0
Ambient Air Temperature
Operation -20 ... +60 °C Storage -40 ... +85 °C
Maximum Operating Altitude Permissible
Without Derating 2000 m
Object Classification Code
B
ETIM 7
EC001438 - Voltage monitoring relay
ETIM 8
EC001438 - Voltage monitoring relay
ETIM 9
EC001438 - Voltage monitoring relay
eClass
V11.0 : 27371801
UNSPSC
39122332
E-Number (Finland)
2712254
E-Number (Norway)
4188090
E-Number (Sweden)
3860620
Manufacturer ID
1SVR730830R0500