Product Model
DS201 M B40 F30

Selling Points
- 1Advanced Overcurrent Protection: Safeguards against overload and short-circuit currents.
- 2High-Frequency Detection: Detects high-frequency currents up to 1 kHz.
- 3Direct Pulsating Earth Fault Protection: Guards against sinusoidal alternating and direct pulsating earth fault currents.
- 4Indirect and Direct Contact Protection: Offers additional protection against indirect contacts and direct contacts.
- 5Compliance with IEC Standards: Meets IEC/EN 61009-1 and IEC/EN 61009-2-1 standards for reliability and safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Standards | IEC/EN 61009-1, IEC/EN 61009-2-1 | Tripping Characteristic | B |
Type of Residual Current | Type F | Rated Operational Voltage | acc. to IEC 60898-1 240 V |
Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V | Test Voltage (Ut) | 170 ... 264 V |
Rated Impulse Withstand Voltage (Uimp) | 4 kV | Dielectric Test Voltage | 2 kV |
Input Voltage Type | AC | Rated Current (In) | 40 A |
Rated Residual Current | 30 mA | Rated Short-Circuit Capacity | 10 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 15 kA | Rated Residual Breaking Capacity (IΔm) | EN 61009-1 6000 A IEC 61009-1 4500 A |
Rated Conditional Short-Circuit Current (Inc) | 15 kA | Rated Service Short-Circuit Breaking Capacity (Ics) | 11.2 kA |
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 10 kA | Maximum Surge Current | 0 kA |
Rated Frequency (f) | 50 ⦠60 Hz | Power Loss | Average per Pole 4.6 W Phase Pole 5.0 W Neutral Pole 4.1 W Total 9.1 W |
Power Supply Connection | Arbitrary | Contact Position Indication | Red ON / Green OFF |
Energy Limiting Class | 3 | Electrical Endurance | 10000 cycle |
Mechanical Endurance | 20000 cycle | Number of Protected Poles | 1 |
Number of Poles | 2 | Number of Modular Spacings per DIN Rail | 2 |
Fault Indication | Blue flag on toggle | Operating Characteristic | Instantaneous (APR High Immunity) |
Overvoltage Category | III | Position of Neutral Terminals | Right |
Tightening Torque | 2.8 N·m | Accessory Type | Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device |
Actuator Type | Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions | Earthing Switch Type | Undelayed |
Housing Type | Insulation group I - II, RAL 7035 | Mounting Type | DIN-Rail |
Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal | Mounting Position | Any |
Accessories Available | Yes | Number of Batteries | 0 |
Connecting Capacity | Busbar 10 ... 10 mm² Stranded 0.75 ... 25 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm² | Rated Cross-Section | 1 - Solid-Core 0.75-25 mm² 4 - Multi-Wired 0.75-16 mm² |
Wire Stripping Length | 12 mm | Terminal Type | Screw Terminals |
Ambient Air Temperature | Operation -25 ⦠55 °C | Reference Ambient Air Temperature | 30 °C |
Degree of Protection | IP20 IP40 | Pollution Degree | 2 |
Environmental Conditions | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % | Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 ⦠150 ⦠5 Hz |
Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms | Environmental Information | 2CSC422002K2701 |
Width in Number of Modular Spacings | 2 | Product Net Width | 35 mm |
Product Net Height | 85 mm | Product Net Depth / Length | 69 mm |
Product Net Weight | 200 g | Built-In Depth (t2) | 69 mm |
ETIM 8 | EC000905 - Earth leakage circuit breaker | ETIM 9 | EC000905 - Earth leakage circuit breaker |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | WEEE B2C / B2B | Business To Consumer |
CN8 | 85363030 | eClass | V11.0 : 27142207 |
Object Classification Code | F | Manufacturer ID | 2CSR275580R1405 |
Specifications may be subject to change without notice