ABB DS201T B13 APR30

Selling Points

  • 1Advanced Protection: Provides comprehensive protection against overcurrent and earth fault currents.
  • 2High Immunity: Designed with high immunity features for reliable operation in harsh environments.
  • 3Compact Design: Compact dimensions for easy installation in DIN-rail systems.
  • 4Energy Limiting Class: Meets energy limiting class standards for safe operation.
  • 5Versatile Application: Suitable for residential, commercial, and industrial settings.
Product Details
DS201T B13 APR30
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Standards
IEC 61009-1 IEC 61009-2-1 EN 61009-1 EN 61009-2-1 EN 45545
Tripping Characteristic
B
Type of Residual Current
Type APR
Application
Traction
Rated Operational Voltage
acc. to IEC 60898-1 230 V
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 500 V
Test Voltage (Ut)
170 ... 264 V
Rated Impulse Withstand Voltage (Uimp)
4 kV
Dielectric Test Voltage
2 kV
Input Voltage Type
AC
Rated Current (In)
13 A
Rated Residual Current
30 mA
Rated Short-Circuit Capacity
6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
10 kA
Rated Residual Breaking Capacity (IΔm)
EN 61009-1 6000 A IEC 61009-1 6000 A
Rated Service Short-Circuit Breaking Capacity (Ics)
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)
6 kA
Maximum Surge Current
3 kA
Rated Frequency (f)
50 … 60 Hz
Power Loss
Average per Pole 1.7 W Phase Pole 2.7 W Neutral Pole 0.8 W Total 3.5 W
Power Supply Connection
Arbitrary
Contact Position Indication
Red ON / Green OFF
Energy Limiting Class
3
Electrical Endurance
10000 cycle
Mechanical Endurance
20000 cycle
Number of Protected Poles
1
Number of Poles
2
Number of Modular Spacings per DIN Rail
2
Fault Indication
Blue flag on toggle
Operating Characteristic
Instantaneous (APR High Immunity)
Overvoltage Category
III
Position of Neutral Terminals
Right
Tightening Torque
2.8 N·m
Accessory Type
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator Type
Toggle - Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Earthing Switch Type
Short-Time Delayed
Housing Type
Insulation group I - II, RAL 7035
Mounting Type
DIN-Rail
Screw Terminal Type
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided
Suitable for traction applications
Mounting Position
Any
Accessories Available
Yes
Surge Immunity acc. to IEC 61000-4-5
3000 A
Number of Batteries
0
Connecting Capacity
Busbar 10 ... 10 mm² Stranded 0.75 ... 25 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm²
Rated Cross-Section
1 - Solid-Core 0.75 … 25 mm² 4 - Multi-Wired 0.75 … 16 mm²
Wire Stripping Length
12 mm
Terminal Type
Screw Terminals
Ambient Air Temperature
Operation -25 … 55 °C
Reference Ambient Air Temperature
30 °C
Degree of Protection
IP20 IP40
Pollution Degree
2
Environmental Conditions
28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Resistance to Vibrations
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27
25g 2 shocks 13 ms
Environmental Information
2CSC422002K2701
Width in Number of Modular Spacings
2
Product Net Width
35 mm
Product Net Height
85 mm
Product Net Depth / Length
69 mm
Product Net Weight
182 g
Built-In Depth (t2)
35 mm
ETIM 8
EC000905 - Earth leakage circuit breaker
ETIM 9
EC000905 - Earth leakage circuit breaker
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Consumer
CN8
85363010
UNSPSC
39121601
eClass
V11.0 : 27142207
IDEA Granular Category Code (IGCC)
4875 >> Residual current circuit breaker (RCCB)
Object Classification Code
F
Manufacturer ID
2CSR255488R1135