ABB DS201T C20 APR30

Selling Points

  • 1Advanced Protection: Provides comprehensive protection against overload and short-circuit currents.
  • 2High Current Rating: Rated for 20 A with a short-circuit breaking capacity of 10 kA.
  • 3Energy Limiting Class: Designed for 10,000 cycles of energy limiting, ensuring reliable operation.
  • 4Compact Design: Ideal for DIN rail mounting, offering a compact and space-efficient solution.
  • 5Enhanced Safety Features: Includes a residual current of 30 mA for added safety against indirect contacts and direct contacts.
Product Details
DS201T C20 APR30
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Standards
IEC 61009-1 IEC 61009-2-1 EN 61009-1 EN 61009-2-1 EN 45545
Tripping Characteristic
C
Type of Residual Current
Type APR
Application
Traction
Rated Operational Voltage
acc. to IEC 60898-1 230 V
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 500 V
Test Voltage (Ut)
170 ... 264 V
Rated Impulse Withstand Voltage (Uimp)
4 kV
Dielectric Test Voltage
2 kV
Input Voltage Type
AC
Rated Current (In)
20 A
Rated Residual Current
30 mA
Rated Short-Circuit Capacity
6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
10 kA
Rated Residual Breaking Capacity (IΔm)
EN 61009-1 6000 A IEC 61009-1 6000 A
Rated Service Short-Circuit Breaking Capacity (Ics)
7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)
6 kA
Maximum Surge Current
3 kA
Rated Frequency (f)
50 … 60 Hz
Power Loss
Average per Pole 2.8 W Phase Pole 3.8 W Neutral Pole 1.8 W Total 5.7 W
Power Supply Connection
Arbitrary
Contact Position Indication
Red ON / Green OFF
Energy Limiting Class
3
Electrical Endurance
10000 cycle
Mechanical Endurance
20000 cycle
Number of Protected Poles
1
Number of Poles
2
Number of Modular Spacings per DIN Rail
2
Fault Indication
Blue flag on toggle
Operating Characteristic
Instantaneous (APR High Immunity)
Overvoltage Category
III
Position of Neutral Terminals
Right
Tightening Torque
2.8 N·m
Accessory Type
Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator Type
Toggle - Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Earthing Switch Type
Short-Time Delayed
Housing Type
Insulation group I - II, RAL 7035
Mounting Type
DIN-Rail
Screw Terminal Type
Failsafe Bi-directional Cylinder-lift Terminal
Options Provided
Suitable for traction applications
Mounting Position
Any
Accessories Available
Yes
Surge Immunity acc. to IEC 61000-4-5
3000 A
Number of Batteries
0
Connecting Capacity
Busbar 10 ... 10 mm² Stranded 0.75 ... 25 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm²
Rated Cross-Section
1 - Solid-Core 0.75 … 25 mm² 4 - Multi-Wired 0.75 … 16 mm²
Wire Stripping Length
12 mm
Terminal Type
Screw Terminals
Ambient Air Temperature
Operation -25 … 55 °C
Reference Ambient Air Temperature
30 °C
Degree of Protection
IP20 IP40
Pollution Degree
2
Environmental Conditions
28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Resistance to Vibrations
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27
25g 2 shocks 13 ms
Environmental Information
2CSC422002K2701
Width in Number of Modular Spacings
2
Product Net Width
35 mm
Product Net Height
85 mm
Product Net Depth / Length
69 mm
Product Net Weight
182 g
Built-In Depth (t2)
35 mm
ETIM 8
EC000905 - Earth leakage circuit breaker
ETIM 9
EC000905 - Earth leakage circuit breaker
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Consumer
CN8
85363010
UNSPSC
39121601
eClass
V11.0 : 27142207
IDEA Granular Category Code (IGCC)
4875 >> Residual current circuit breaker (RCCB)
Object Classification Code
F
Manufacturer ID
2CSR255488R1204

Specifications may be subject to change without notice