Product Model
DS201T C25 A30

Selling Points
- 1Comprehensive Protection: Safeguards against overcurrent, short-circuit, and earth fault currents.
- 2High Sensitivity: Detects residual currents as low as 30 mA for enhanced safety.
- 3Compact Design: Two-module width for easy installation in DIN rail systems.
- 4Versatile Applications: Suitable for residential, commercial, and industrial use.
- 5Robust Construction: Meets IEC 61009-1 and IEC 61009-2-1 standards for reliability and durability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Standards | IEC 61009-1 IEC 61009-2-1 EN 61009-1 EN 61009-2-1 EN 45545 | Tripping Characteristic | C |
Type of Residual Current | Type A | Application | Traction |
Rated Operational Voltage | acc. to IEC 60898-1 230 V | Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
Test Voltage (Ut) | 170 ... 264 V | Rated Impulse Withstand Voltage (Uimp) | 4 kV |
Dielectric Test Voltage | 2 kV | Input Voltage Type | AC |
Rated Current (In) | 25 A | Rated Residual Current | 30 mA |
Rated Short-Circuit Capacity | 6 kA | Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 10 kA |
Rated Residual Breaking Capacity (IΔm) | EN 61009-1 6000 A IEC 61009-1 6000 A | Rated Service Short-Circuit Breaking Capacity (Ics) | 7.5 kA |
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 6 kA | Rated Frequency (f) | 50 ⦠60 Hz |
Power Loss | Average per Pole 4.1 W Phase Pole 5.5 W Neutral Pole 2.6 W Total 8.1 W | Power Supply Connection | Arbitrary |
Contact Position Indication | Red ON / Green OFF | Energy Limiting Class | 3 |
Electrical Endurance | 10000 cycle | Mechanical Endurance | 20000 cycle |
Number of Protected Poles | 1 | Number of Poles | 2 |
Number of Modular Spacings per DIN Rail | 2 | Fault Indication | Blue flag on toggle |
Operating Characteristic | Instantaneous | Overvoltage Category | III |
Position of Neutral Terminals | Right | Tightening Torque | 2.8 N·m |
Accessory Type | Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device | Actuator Type | Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions |
Earthing Switch Type | Undelayed | Housing Type | Insulation group I - II, RAL 7035 |
Mounting Type | DIN-Rail | Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
Options Provided | Suitable for traction applications | Mounting Position | Any |
Accessories Available | Yes | Number of Batteries | 0 |
Connecting Capacity | Busbar 10 ... 10 mm² Stranded 0.75 ... 25 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm² | Rated Cross-Section | 1 - Solid-Core 0.75 ⦠25 mm² 4 - Multi-Wired 0.75 ⦠16 mm² |
Wire Stripping Length | 12 mm | Terminal Type | Screw Terminals |
Ambient Air Temperature | Operation -25 ⦠55 °C | Reference Ambient Air Temperature | 30 °C |
Degree of Protection | IP20 IP40 | Pollution Degree | 2 |
Environmental Conditions | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % | Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 ⦠150 ⦠5 Hz |
Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms | Environmental Information | 2CSC422002K2701 |
Width in Number of Modular Spacings | 2 | Product Net Width | 35 mm |
Product Net Height | 85 mm | Product Net Depth / Length | 69 mm |
Product Net Weight | 182 g | Built-In Depth (t2) | 35 mm |
ETIM 8 | EC000905 - Earth leakage circuit breaker | ETIM 9 | EC000905 - Earth leakage circuit breaker |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | WEEE B2C / B2B | Business To Consumer |
CN8 | 85363010 | UNSPSC | 39121601 |
eClass | V11.0 : 27142207 | IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
Object Classification Code | F | Manufacturer ID | 2CSR255188R1254 |