Product Model
ESB25-13N-07

Selling Points
- 1Reliable Performance: The ABB ESB25-13N-07 contactor ensures consistent operation in 400-415 V AC/DC environments, making it suitable for various industrial applications.
- 2Safety Configuration: Equipped with a 1NO + 3NC configuration, this contactor provides enhanced safety features, ensuring reliable switching and protection.
- 3DIN Rail Mounting: Designed for easy installation, the ESB25-13N-07 can be mounted on DIN rails, simplifying setup and maintenance.
- 4High Current Rating: With a contact current rating of 25 A, this contactor is capable of handling significant electrical loads, making it ideal for demanding applications.
- 5Global Availability: Available worldwide through leading distributors, ensuring easy access to this high-quality contactor solution.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 36 mm | Product Net Height | 85 mm |
Product Net Depth / Length | 65 mm | Product Net Weight | 0.235 kg |
Rated Operational Voltage | Main Circuit 220 V DC Main Circuit 400 V AC | Rated Control Circuit Voltage (Uc) | 400 ... 415 V |
Rated Frequency (f) | Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz Main Circuit DC | Rated Operational Current AC-1 (Ie) | (NC) 25 A (NO) 25 A |
Rated Operational Current AC-3 (Ie) | (230 V) Single Phase, NC 6 A (230 V) Single Phase, NO 9 A (400 V) Three Phase, NC 6 A | Rated Operational Power AC-1 (Pe) | (230 V) Single Phase, NC 5.8 kW (400 V) Three Phase, NC 17.3 kW (230 V) Single Phase, NO 5.8 kW |
Rated Operational Power AC-3 (Pe) | (230 V) Single Phase, NC 0.9 kW (230 V) Single Phase, NO 1.3 kW (400 V) Three Phase, NC 2.7 kW | Rated Operational Current AC-7a (Ie) | (NC) 25 A (NO) 25 A |
Rated Operational Power AC-7a (Pe) | (230 V) Single Phase, NC 5.8 kW (230 V) Single Phase, NO 5.8 kW (400 V) Three Phase, NC 17.25 kW | Rated Operational Current AC-7b (Ie) | (230 V) Single Phase, NC 6 A (230 V) Single Phase, NO 9 A (400 V) Three Phase, NC 6 A |
Rated Operational Power AC-7b (Pe) | (230 V) Single Phase, NC 0.9 kW (230 V) Single Phase, NO 1.3 kW (400 V) Three Phase, NC 2.7 kW | Recommended Screw Driver | Control Circuit Pozidriv 1 Main Circuit Pozidriv 1 |
Rated Impulse Withstand Voltage (Uimp) | 6 kV | Rated Insulation Voltage (Ui) | 500 V |
Connecting Capacity Main Circuit | Flexible with Ferrule 1x 1.5 ... 10 mm² Flexible with Ferrule 2x 1.5 ... 2.5 mm² Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² Flexible with Insulated Ferrule 2x 1.5 mm² Flexible 1x 1.5 ... 10 mm² Flexible 2x 1.5 ... 4 mm² Rigid 1x 1.5 ... 10 mm² Rigid 2x 1.5 ... 4 mm² | Connecting Capacity Control Circuit | Flexible with Ferrule 1x 1 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1 mm² Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 4.0 mm² Flexible 2x 1 ... 2.5 mm² Rigid 1x 1 ... 4 mm² Rigid 2x 1 ... 2.5 mm² |
Tightening Torque | Control Circuit 0.9 N·m Main Circuit 1 N·m | Wire Stripping Length | Control Circuit 7 mm Main Circuit 10 mm |
Degree of Protection | IP20 | Electrical Durability | AC-1 (NC) 50000 cycle AC-1 (NO) 130000 cycle AC-3 (NC) 340000 cycle AC-3 (NO) 500000 cycle AC-7a (NC) 50000 cycle AC-7a (NO) 130000 cycle AC-7b (NC) 340000 cycle AC-7b (NO) 500000 cycle |
Mechanical Durability | 1000000 cycle | Number of Poles | 4 |
Number of Auxiliary Contacts NC | 0 | Number of Auxiliary Contacts NO | 0 |
Number of Main Contacts NC | 3 | Number of Main Contacts NO | 1 |
Width in Number of Modular Spacings | 2.0 | Pollution Degree | 3 |
Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 61095 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L | Maximum Operating Voltage UL/CSA | Main Circuit 480 V AC |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Single Phase, NC 1 Hp (220 ... 240 V AC) Single Phase, NO 1 Hp (220 ... 240 V AC) Three Phase, NC 3 Hp (440 ... 480 V AC) Single Phase, NC 0.5 Hp (440 ... 480 V AC) Single Phase, NO 2 Hp (440 ... 480 V AC) Three Phase, NC 2 Hp | Connecting Capacity Main Circuit UL/CSA | Solid 16-8 AWG Stranded 16-8 AWG |
Connecting Capacity Control Circuit UL/CSA | Solid 16-10 AWG Stranded 16-10 AWG | Tightening Torque UL/CSA | Control Circuit 8 in·lb Main Circuit 9 in·lb |
Ambient Air Temperature | Operation -25 ... +55 °C Storage -40 ... +80 °C | Maximum Operating Altitude Permissible | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g | RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
Object Classification Code | Q | ETIM 5 | EC001653 - Installation contactor for distribution board |
ETIM 6 | EC001653 - Installation contactor for distribution board | ETIM 7 | EC001653 - Installation contactor for distribution board |
eClass | V11.0 : 27142308 | UNSPSC | 39121529 |
IDEA Granular Category Code (IGCC) | 4759 >> Installation contactor for distribution board | ETIM 8 | EC001653 - Installation contactor for distribution board |
Manufacturer ID | 1SAE231111M0713 |
Specifications may be subject to change without notice