Product Model

ESB25-13N-07

In Stock
Last updated: 2025/4/21
ABB ESB25-13N-07

Selling Points

  • 1Reliable Performance: The ABB ESB25-13N-07 contactor ensures consistent operation in 400-415 V AC/DC environments, making it suitable for various industrial applications.
  • 2Safety Configuration: Equipped with a 1NO + 3NC configuration, this contactor provides enhanced safety features, ensuring reliable switching and protection.
  • 3DIN Rail Mounting: Designed for easy installation, the ESB25-13N-07 can be mounted on DIN rails, simplifying setup and maintenance.
  • 4High Current Rating: With a contact current rating of 25 A, this contactor is capable of handling significant electrical loads, making it ideal for demanding applications.
  • 5Global Availability: Available worldwide through leading distributors, ensuring easy access to this high-quality contactor solution.
Product Details
ESB25-13N-07
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
36 mm
Product Net Height
85 mm
Product Net Depth / Length
65 mm
Product Net Weight
0.235 kg
Rated Operational Voltage
Main Circuit 220 V DC Main Circuit 400 V AC
Rated Control Circuit Voltage (Uc)
400 ... 415 V
Rated Frequency (f)
Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz Main Circuit DC
Rated Operational Current AC-1 (Ie)
(NC) 25 A (NO) 25 A
Rated Operational Current AC-3 (Ie)
(230 V) Single Phase, NC 6 A (230 V) Single Phase, NO 9 A (400 V) Three Phase, NC 6 A
Rated Operational Power AC-1 (Pe)
(230 V) Single Phase, NC 5.8 kW (400 V) Three Phase, NC 17.3 kW (230 V) Single Phase, NO 5.8 kW
Rated Operational Power AC-3 (Pe)
(230 V) Single Phase, NC 0.9 kW (230 V) Single Phase, NO 1.3 kW (400 V) Three Phase, NC 2.7 kW
Rated Operational Current AC-7a (Ie)
(NC) 25 A (NO) 25 A
Rated Operational Power AC-7a (Pe)
(230 V) Single Phase, NC 5.8 kW (230 V) Single Phase, NO 5.8 kW (400 V) Three Phase, NC 17.25 kW
Rated Operational Current AC-7b (Ie)
(230 V) Single Phase, NC 6 A (230 V) Single Phase, NO 9 A (400 V) Three Phase, NC 6 A
Rated Operational Power AC-7b (Pe)
(230 V) Single Phase, NC 0.9 kW (230 V) Single Phase, NO 1.3 kW (400 V) Three Phase, NC 2.7 kW
Recommended Screw Driver
Control Circuit Pozidriv 1 Main Circuit Pozidriv 1
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
500 V
Connecting Capacity Main Circuit
Flexible with Ferrule 1x 1.5 ... 10 mm² Flexible with Ferrule 2x 1.5 ... 2.5 mm² Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² Flexible with Insulated Ferrule 2x 1.5 mm² Flexible 1x 1.5 ... 10 mm² Flexible 2x 1.5 ... 4 mm² Rigid 1x 1.5 ... 10 mm² Rigid 2x 1.5 ... 4 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1x 1 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1 mm² Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 4.0 mm² Flexible 2x 1 ... 2.5 mm² Rigid 1x 1 ... 4 mm² Rigid 2x 1 ... 2.5 mm²
Tightening Torque
Control Circuit 0.9 N·m Main Circuit 1 N·m
Wire Stripping Length
Control Circuit 7 mm Main Circuit 10 mm
Degree of Protection
IP20
Electrical Durability
AC-1 (NC) 50000 cycle AC-1 (NO) 130000 cycle AC-3 (NC) 340000 cycle AC-3 (NO) 500000 cycle AC-7a (NC) 50000 cycle AC-7a (NO) 130000 cycle AC-7b (NC) 340000 cycle AC-7b (NO) 500000 cycle
Mechanical Durability
1000000 cycle
Number of Poles
4
Number of Auxiliary Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Main Contacts NC
3
Number of Main Contacts NO
1
Width in Number of Modular Spacings
2.0
Pollution Degree
3
Standards
IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 61095 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSA
Main Circuit 480 V AC
Horsepower Rating UL/CSA
(220 ... 240 V AC) Single Phase, NC 1 Hp (220 ... 240 V AC) Single Phase, NO 1 Hp (220 ... 240 V AC) Three Phase, NC 3 Hp (440 ... 480 V AC) Single Phase, NC 0.5 Hp (440 ... 480 V AC) Single Phase, NO 2 Hp (440 ... 480 V AC) Three Phase, NC 2 Hp
Connecting Capacity Main Circuit UL/CSA
Solid 16-8 AWG Stranded 16-8 AWG
Connecting Capacity Control Circuit UL/CSA
Solid 16-10 AWG Stranded 16-10 AWG
Tightening Torque UL/CSA
Control Circuit 8 in·lb Main Circuit 9 in·lb
Ambient Air Temperature
Operation -25 ... +55 °C Storage -40 ... +80 °C
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 15g
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Object Classification Code
Q
ETIM 5
EC001653 - Installation contactor for distribution board
ETIM 6
EC001653 - Installation contactor for distribution board
ETIM 7
EC001653 - Installation contactor for distribution board
eClass
V11.0 : 27142308
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4759 >> Installation contactor for distribution board
ETIM 8
EC001653 - Installation contactor for distribution board
Manufacturer ID
1SAE231111M0713

Specifications may be subject to change without notice