ABB F202 A-100/0.1

Selling Points

  • 1The F202 A-100/0.1 RCCB offers robust protection against fault currents to earth, ensuring safety in electrical installations.
  • 2This circuit breaker provides selective protection, allowing it to distinguish between line and earth faults, reducing unnecessary tripping.
  • 3Built with a durable design, the F202 A-100/0.1 can withstand harsh environmental conditions, including temperatures ranging from -25°C to 55°C.
  • 4Designed for DIN rail mounting, the F202 A-100/0.1 is easy to install and integrate into existing electrical systems.
  • 5Manufactured according to international IEC standards, ensuring compliance and reliability in global markets.
Product Details
F202 A-100/0.1
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Standards
IEC/EN 61008 UL 1053
Type of Residual Current
Type A
Rated Voltage (Ur)
230 V
Rated Operational Voltage
230 V
Rated Insulation Voltage (Ui)
500 V
Test Voltage (Ut)
110-254 V
Rated Impulse Withstand Voltage (Uimp)
4 kV
Input Voltage Type
AC
Rated Current (In)
100 A
Rated Residual Current
100 mA
Rated Conditional Short-Circuit Current (Inc)
10 kA
Leakage Current Type
A
Frequency (f)
50/60 Hz
Rated Frequency (f)
50 … 60 Hz
Power Loss
at Rated Operating Conditions per Pole 6.5 W
Power Supply Connection
Arbitrary
Electrical Endurance
10000 cycle
Number of Poles
2
Number of Modular Spacings per DIN Rail
2
Operating Characteristic
Instantaneous
Tightening Torque
2.8 N·m
Accessory Type
Auxiliary contact Signal / auxiliary contact Shunt trip Auto re-closing units Motor operating device Overvoltage release Undervoltage release
Mounting Type
DIN-Rail
Options Provided
None
Mounting Position
Any
Accessories Available
Yes
Connecting Capacity
Busbar 10 mm² Rigid 35 ... 35 mm² Flexible 35 ... 35 mm²
Rated Cross-Section
4 - Multi-Wired 0...35 mm² 1 - Solid-Core 35...35 mm²
Wire Stripping Length
Top 12.7 mm Bottom 14.9 mm
Terminal Type
Screw Terminals
Ambient Air Temperature
Operation -25 ... 55 °C Storage -40 ... 70 °C
Degree of Protection
IP2X
Pollution Degree
2
Resistance to Vibrations
20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27
25g 2 shocks 13 ms
Environmental Information
Refer to RoHS
Maximum Operating Voltage UL/CSA
277 V AC
Short-Circuit Current Rating (SCCR)
100 mA
Width in Number of Modular Spacings
2
Product Net Width
35 mm
Product Net Height
85 mm
Product Net Depth / Length
69 mm
Product Net Weight
200 g
Built-In Depth (t2)
69 mm
ETIM 8
EC000003 - Residual current circuit breaker (RCCB)
ETIM 9
EC000003 - Residual current circuit breaker (RCCB)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Consumer
CN8
85363030
UNSPSC
39121601
eClass
V11.0 : 27142201
IDEA Granular Category Code (IGCC)
4875 >> Residual current circuit breaker (RCCB)
Object Classification Code
F
Manufacturer ID
2CSF202101R2900

Specifications may be subject to change without notice