Product Model
F202 A-40/0.1

Selling Points
- 1Ensures safety by detecting and interrupting fault currents to earth.
- 2Provides precise detection and tripping for enhanced protection.
- 3Suitable for a wide range of applications requiring up to 40A.
- 4Easy installation on DIN rails for compact and efficient setup.
- 5Designed for use in AC low voltage systems, ensuring reliable operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Standards | IEC/EN 61008 UL 1053 | Type of Residual Current | Type A |
Rated Voltage (Ur) | 230 V | Rated Operational Voltage | 230 V |
Rated Insulation Voltage (Ui) | 500 V | Test Voltage (Ut) | 110-254 V |
Rated Impulse Withstand Voltage (Uimp) | 4 kV | Input Voltage Type | AC |
Rated Current (In) | 40 A | Rated Residual Current | 100 mA |
Rated Conditional Short-Circuit Current (Inc) | 10 kA | Leakage Current Type | A |
Frequency (f) | 50/60 Hz | Rated Frequency (f) | 50 ⦠60 Hz |
Power Loss | at Rated Operating Conditions per Pole 2.4 W | Power Supply Connection | Arbitrary |
Electrical Endurance | 10000 cycle | Number of Poles | 2 |
Number of Modular Spacings per DIN Rail | 2 | Operating Characteristic | Instantaneous |
Tightening Torque | 2.8 N·m | Accessory Type | Auxiliary contact Signal / auxiliary contact Shunt trip Auto re-closing units Motor operating device Overvoltage release Undervoltage release Home automatic resetting unit |
Mounting Type | DIN-Rail | Options Provided | None |
Mounting Position | Any | Accessories Available | Yes |
Connecting Capacity | Busbar 10 mm² Rigid 25 ... 25 mm² Flexible 25 ... 25 mm² | Rated Cross-Section | 4 - Multi-Wired 0...25 mm² 1 - Solid-Core 25...25 mm² |
Wire Stripping Length | 12 mm | Terminal Type | Screw Terminals |
Ambient Air Temperature | Operation -25 ... 55 °C Storage -40 ... 70 °C | Degree of Protection | IP2X |
Pollution Degree | 2 | Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 ⦠150 ⦠5 Hz |
Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms | Environmental Information | Refer to RoHS |
Maximum Operating Voltage UL/CSA | 277 V AC | Short-Circuit Current Rating (SCCR) | 100 mA |
Width in Number of Modular Spacings | 2 | Product Net Width | 35 mm |
Product Net Height | 85 mm | Product Net Depth / Length | 69 mm |
Product Net Weight | 200 g | Built-In Depth (t2) | 69 mm |
ETIM 8 | EC000003 - Residual current circuit breaker (RCCB) | ETIM 9 | EC000003 - Residual current circuit breaker (RCCB) |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | WEEE B2C / B2B | Business To Consumer |
CN8 | 85363030 | UNSPSC | 39121601 |
eClass | V11.0 : 27142201 | IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
Object Classification Code | F | Manufacturer ID | 2CSF202101R2400 |
Specifications may be subject to change without notice