Product Model
F204 A-25/0.03-L

Selling Points
- 1Safeguards against sinusoidal alternating and direct pulsating earth fault currents.
- 2Provides additional protection against direct contacts with a sensitivity of 30 mA.
- 3Suitable for residential, commercial, and industrial settings.
- 4Meets IEC/EN 61008 standards for reliability and performance.
- 5Easy to install on DIN rail with a compact footprint.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Standards | IEC/EN 61008 | Type of Residual Current | Type A |
Rated Voltage (Ur) | 230/400 V | Rated Operational Voltage | 230 / 400 V AC |
Rated Insulation Voltage (Ui) | 500 V | Test Voltage (Ut) | 300-440 V |
Rated Impulse Withstand Voltage (Uimp) | 4 kV | Input Voltage Type | AC |
Rated Current (In) | 25 A | Rated Residual Current | 30 mA |
Rated Conditional Short-Circuit Current (Inc) | 10 kA | Leakage Current Type | A |
Frequency (f) | 50/60 Hz | Rated Frequency (f) | 50 ⦠60 Hz |
Power Loss | at Rated Operating Conditions per Pole 1.3 W | Power Supply Connection | Arbitrary |
Electrical Endurance | 10000 cycle | Number of Poles | 4 |
Number of Modular Spacings per DIN Rail | 4 | Operating Characteristic | Instantaneous |
Position of Neutral Terminals | Left | Tightening Torque | 2.8 N·m |
Accessory Type | Auxiliary contact Signal / auxiliary contact Shunt trip Auto re-closing units Motor operating device Overvoltage release Undervoltage release | Mounting Type | DIN-Rail |
Options Provided | None | Mounting Position | Any |
Accessories Available | Yes | Connecting Capacity | Busbar 10 mm² Rigid 25 ... 25 mm² Flexible 25 ... 25 mm² |
Rated Cross-Section | 4 - Multi-Wired 0...25 mm² 1 - Solid-Core 25...25 mm² | Wire Stripping Length | 12 mm |
Terminal Type | Screw Terminals | Ambient Air Temperature | Operation -25 ... 55 °C Storage -40 ... 70 °C |
Degree of Protection | IP2X | Pollution Degree | 2 |
Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 ⦠150 ⦠5 Hz | Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
Environmental Information | Refer to RoHS | Short-Circuit Current Rating (SCCR) | 30 mA |
Width in Number of Modular Spacings | 4 | Product Net Width | 70 mm |
Product Net Height | 85 mm | Product Net Depth / Length | 69 mm |
Product Net Weight | 360 g | Built-In Depth (t2) | 69 mm |
Dimension Diagram | 9AKK106354A0759 | ETIM 8 | EC000003 - Residual current circuit breaker (RCCB) |
ETIM 9 | EC000003 - Residual current circuit breaker (RCCB) | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
WEEE B2C / B2B | Business To Consumer | CN8 | 85363030 |
UNSPSC | 39121601 | eClass | V11.0 : 27142201 |
IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) | Object Classification Code | F |
Manufacturer ID | 2CSF204123R1250 |
Specifications may be subject to change without notice