Product Model
GAF300-10-11-72

Selling Points
- 1500 A at 1000 V for robust performance.
- 2Operates with 20-60 VDC coil voltage for flexibility.
- 3140 mm W x 180.5 mm D x 227 mm H dimensions for space efficiency.
- 4Up to 5 million cycles for extended service life.
- 5Suitable for various applications including solar, traction, and power distribution systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 140 mm | Product Net Depth / Length | 180.5 mm |
Product Net Height | 227 mm | Product Net Weight | 5.5 kg |
Number of Main Contacts NO | 1 | Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 | Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V | Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Π= 40 °C 500 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A | Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 500 A (1000 V) 3 Poles in Series, 55 °C 400 A (1000 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 500 A (220 V) 3 Poles in Series, 55 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (400 V) 3 Poles in Series, 40 °C 500 A (400 V) 3 Poles in Series, 55 °C 400 A (400 V) 3 Poles in Series, 70 °C 325 A (600 V) 3 Poles in Series, 40 °C 500 A (600 V) 3 Poles in Series, 55 °C 400 A (600 V) 3 Poles in Series, 70 °C 325 A |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V | Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
Mechanical Durability | 5 million | Maximum Mechanical Switching Frequency | 300 cycles per hour |
Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ⤠70 °C) | Rated Control Circuit Voltage (Uc) | DC Operation 20 ... 60 V |
Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A Holding at Max. Rated Control Circuit Voltage DC 2 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A Pull-in at Max. Rated Control Circuit Voltage DC 520 V·A | Connecting Capacity Main Circuit | Bar 32 mm² Rigid Al-Cable 2 x 95 ... 120 mm² Rigid Cu-Cable 16 ... 240 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 1 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² | Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
Terminal Type | Main Circuit: Bars | Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
General Use Rating UL/CSA | (1000 V DC) 400 A (440 V DC) 400 A (600 V DC) 400 A | Ambient Air Temperature | Operation -40 ... 70 °C Storage -40 ... +70 °C |
Maximum Operating Altitude Permissible | Without Derating 3000 m | Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g |
Object Classification Code | Q | ETIM 7 | EC002552 - Power contactor, DC switching |
ETIM 8 | EC002552 - Power contactor, DC switching | ETIM 9 | EC002552 - Power contactor, DC switching |
eClass | V11.0 : 27371018 | UNSPSC | 39121529 |
IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching | Manufacturer ID | 1SFL557025R7211 |
Specifications may be subject to change without notice