Product Model
GAF460-10-11-70

Selling Points
- 1High-Performance DC Contactor: Designed for DC-1 applications with 3 poles in series, up to 1000VDC.
- 2Wide Control Voltage Range: Operates with control voltage range of 100-250V AC/DC.
- 3High Current Rating: Supports 700A at 1000V, ensuring reliable operation in demanding conditions.
- 4Long Operating Cycles: Capable of 5 million operating cycles, extending the lifespan of the contactor.
- 5Durable Construction: Built with robust materials and designed for -40 to 70°C operating temperature range.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 186 mm | Product Net Depth / Length | 216 mm |
Product Net Height | 278 mm | Product Net Weight | 10.6 kg |
Number of Main Contacts NO | 1 | Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 | Number of Auxiliary Contacts NC | 1 |
Rated Operational Voltage | Main Circuit 1000 V | Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Π= 40 °C 700 A |
Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 700 A (1000 V) 3 Poles in Series, 55 °C 600 A (1000 V) 3 Poles in Series, 70 °C 480 A (220 V) 3 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 55 °C 600 A (220 V) 3 Poles in Series, 70 °C 480 A (400 V) 3 Poles in Series, 40 °C 700 A (400 V) 3 Poles in Series, 55 °C 600 A (400 V) 3 Poles in Series, 70 °C 480 A (600 V) 3 Poles in Series, 40 °C 700 A (600 V) 3 Poles in Series, 55 °C 600 A (600 V) 3 Poles in Series, 70 °C 480 A | Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV | Mechanical Durability | 3 million |
Maximum Mechanical Switching Frequency | 300 cycles per hour | Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ⤠70 °C) |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V | Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage DC 4 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 890 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 890 V·A Pull-in at Max. Rated Control Circuit Voltage DC 990 V·A |
Connecting Capacity Main Circuit | Bar 47 mm² Rigid Al-Cable 2x240 mm² Rigid Cu-Cable 240 mm² | Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | Terminal Type | Main Circuit: Bars |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V | General Use Rating UL/CSA | (1000 V DC) 650 A (440 V DC) 650 A (600 V DC) 650 A |
Ambient Air Temperature | Operation -40 ... 70 °C Storage -40 ... +70 °C | Maximum Operating Altitude Permissible | Without Derating 3000 m |
Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g | Object Classification Code | Q |
ETIM 7 | EC002552 - Power contactor, DC switching | ETIM 8 | EC002552 - Power contactor, DC switching |
ETIM 9 | EC002552 - Power contactor, DC switching | eClass | V11.0 : 27371018 |
UNSPSC | 39121529 | IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |
E-Number (Finland) | 3709745 | Manufacturer ID | 1SFL597025R7011 |
Specifications may be subject to change without notice