Product Model
KC6-40E-P-1.4-81

Selling Points
- 1Compact design for space-optimized control solutions.
- 2Low coil consumption (1.4 W) for energy efficiency.
- 3Noiseless and hum-free coil operation.
- 4Directly controllable by PLC for seamless integration.
- 54NO contacts with a contact rating of 4 A at 24 VAC.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 47.5 mm | Product Net Depth / Length | 51.5 mm |
Product Net Height | 45.5 mm | Product Net Weight | 0.17 kg |
Coil Consumption | Average Holding Value DC 1.4 W Average Pull-in Value DC 1.4 W | Coil Operating Limits | (acc. to IEC 60947-5-1) for DC supply 0.85 ... 1.1 x Uc (at θ ⤠55 °C) |
Maximum Electrical Switching Frequency | (AC-15) 600 cycles per hour (DC-13) 600 cycles per hour | Mechanical Durability | 10000000 cycle |
Mini Contactor Type | Interface Mini Contactor Relay | Minimum Mounting Distance | Other Device Same Type, Horizontal 0 mm |
Minimum Switching Capacity | 17 V 5 mA | Mounting Position | 1 ... 6 |
Mounting Type | DIN-Rail PCB | Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Number of Auxiliary Contacts NC | 0 | Number of Auxiliary Contacts NO | 4 |
Number of Main Contacts NC | 0 | Number of Main Contacts NO | 0 |
Number of Poles | 4 | Power Loss | at Rated Operating Conditions per Pole 0.32 W |
Rated Control Circuit Voltage (Uc) | 24 V DC | Rated Frequency (f) | Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Control Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV | Rated Insulation Voltage (Ui) | 690 V acc. to UL/CSA 600 V |
Rated Operational Current AC-15 (Ie) | (24 V) 4 A (120 V) 4 A (240 V) 4 A (400 V) 3 A (500 V) 2 A | Rated Operational Current DC-13 (Ie) | (24 V) 2.5 A (110 V) 0.7 A (220 / 240 V) 0.4 A |
Rated Operational Voltage | Auxiliary Circuit 690 V AC Auxiliary Circuit 250 V DC | Remarks | No CA6 or CAF6 mountable |
Short-Circuit Protective Devices | gG Type Fuses 6 A | Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L |
Terminal Type | Soldering Pins | Contact Rating UL/CSA | A600 |
General Use Rating UL/CSA | (600 V AC) 5 A | Maximum Operating Voltage UL/CSA | 600 V AC |
Pilot Duty UL/CSA | A600 | Ambient Air Temperature | Operation -25 ... +55 °C Storage -40 ... +80 °C |
Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit 6 A | Degree of Protection | Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 |
Maximum Operating Altitude Permissible | 2000 m | Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
Resistance to Vibrations | 3g 3 ... 150 Hz | eClass | V11.0 : 27371001 |
ETIM 6 | EC000196 - Contactor relay | ETIM 7 | EC000196 - Contactor relay |
ETIM 8 | EC000196 - Contactor relay | ETIM 9 | EC000196 - Contactor relay |
IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching | Object Classification Code | K |
UNSPSC | 39121529 | Manufacturer ID | GJH1213009R8401 |
Specifications may be subject to change without notice