ABB MS132-0.25-HKF1-11

Selling Points

  • 1Compact 45 mm width device with pre-assembled auxiliary contact HKF1-11.
  • 2Rated service short-circuit breaking capacity of 100 kA at 400 VAC.
  • 3Trip class 10 for reliable overload protection and phase failure detection.
  • 4Built-in disconnect function and temperature compensation for enhanced safety.
  • 5Lockable rotary handle for secure operation and unauthorized change prevention.
Product Details
MS132-0.25-HKF1-11
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product Net Width
45 mm
Product Net Height
90 mm
Product Net Depth / Length
86.75 mm
Product Net Weight
0.231 kg
Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
3.1 A
Setting Range
0.16 ... 0.25 A
Rated Operational Power AC-3 (Pe)
(400 V) Three Phase 0.06 kW
Rated Operational Power AC-3e (Pe)
(400 V) Three Phase 0.06 kW
Rated Operational Voltage
Main Circuit 690 V AC Main Circuit 250 V DC
Rated Operational Current (Ie)
0.25 A
Rated Operational Current AC-3 (Ie)
0.25 A
Rated Operational Current AC-3e (Ie)
0.25 A
Rated Operational Current DC-5 (Ie)
0.25 A
Rated Frequency (f)
Main Circuit 50 Hz Main Circuit 60 Hz
Operating Frequency (fsw)
0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 0.7 ... 1.6 W
Number of Poles
3
Mounted Auxiliary Contacts
1 NO, 1 NC
Conventional Free-air Thermal Current (Ith)
Main Circuit 0.25 A
Degree of Protection
Housing IP20 Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 1.5 mm²
Tightening Torque
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Auxiliary Circuit 8 mm Main Circuit 9 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Remarks
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Short-Circuit Current Rating (SCCR)
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSA
Auxiliary Circuit 250 V AC/DC Main Circuit 600 V AC
Full Load Amps Motor Use
(200 V AC) Three Phase 0.25 A (208 V AC) Three Phase 0.25 A (220 ... 240 V AC) Three Phase 0.25 A (440 ... 480 V AC) Three Phase 0.25 A (550 ... 600 V AC) Three Phase 0.25 A
Locked Rotor Amps
(200 V AC) Three Phase 1.5 A (208 V AC) Three Phase 1.5 A (220 ... 240 V AC) Three Phase 1.5 A (440 ... 480 V AC) Three Phase 1.5 A (550 ... 600 V AC) Three Phase 1.5 A
General Use Rating UL/CSA
(600 V AC) 0.25 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 16-14 AWG Stranded 1/2x 16-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb Main Circuit 10 ... 12 in·lb
Contact Rating UL/CSA
B300 R300
Ambient Air Temperature
Operation -25 ... +70 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations
5g 3 ... 150 Hz
Object Classification Code
F
ETIM 4
EC000074 - Motor protective circuit-breaker
ETIM 5
EC000074 - Motor protective circuit-breaker
ETIM 6
EC000074 - Motor protection circuit-breaker
ETIM 7
EC000074 - Motor protection circuit-breaker
ETIM 8
EC000074 - Motor protection circuit-breaker
eClass
V11.0 : 27370401
UNSPSC
39121521
IDEA Granular Category Code (IGCC)
4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
E-Number (Finland)
3705901
Manufacturer ID
1SAM350005R1002