Product Model
MS132-0.25K

Selling Points
- 1Compact design with a width of 45 mm for easy installation.
- 2Reliable protection against short-circuits, overloads, and phase failures.
- 3Trip class 10 for precise fault detection and clear indication.
- 4Built-in disconnect function and temperature compensation for enhanced safety.
- 5Suitable for three- and single-phase applications with a rated operational current of 0.25 A.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product Net Width | 45 mm | Product Net Height | 112 mm |
Product Net Depth / Length | 87 mm | Product Net Weight | 0.256 kg |
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA | Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 3.1 A | Setting Range | 0.16 ... 0.25 A |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 0.06 kW | Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 0.06 kW |
Rated Operational Voltage | Main Circuit 690 V AC Main Circuit 250 V DC | Rated Operational Current (Ie) | 0.25 A |
Rated Operational Current AC-3 (Ie) | 0.25 A | Rated Operational Current AC-3e (Ie) | 0.25 A |
Rated Operational Current DC-5 (Ie) | 0.25 A | Rated Frequency (f) | Main Circuit 50 Hz Main Circuit 60 Hz |
Operating Frequency (fsw) | 0 ... 400 Hz | Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
Rated Insulation Voltage (Ui) | 690 V | Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.6 W |
Number of Poles | 3 | Conventional Free-air Thermal Current (Ith) | Main Circuit 0.25 A |
Degree of Protection | Housing IP20 Main Circuit Terminals IP20 | Pollution Degree | 3 |
Electrical Durability | 50000 cycle | Mechanical Durability | 100000 cycle |
Terminal Type | Push-in Spring Terminals | Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.5 ... 4 mm² Flexible with Insulated Ferrule 1x 0.5 ... 4 mm² Flexible with Insulated Ferrule 2x 0.5 ... 2.5 mm² Flexible 1/2x 0.75 ... 4 mm² Solid 1/2x 1 ... 2.5 mm² Stranded 1/2x 1 ... 6 mm² |
Wire Stripping Length | Main Circuit 12 mm | Recommended Screw Driver | Pozidriv 2 |
Mounting Position | 1 ... 6 | Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm | Actuator Type | Rotary Handle |
Contact Position Indication | ON / OFF / TRIP | Standards | IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L |
Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with terminal spacer TS1-M3-K | Short-Circuit Current Rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA |
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC | Full Load Amps Motor Use | (200 V AC) Three Phase 0.25 A (208 V AC) Three Phase 0.25 A (220 ... 240 V AC) Three Phase 0.25 A (440 ... 480 V AC) Three Phase 0.25 A (550 ... 600 V AC) Three Phase 0.25 A |
Locked Rotor Amps | (200 V AC) Three Phase 1.5 A (208 V AC) Three Phase 1.5 A (220 ... 240 V AC) Three Phase 1.5 A (440 ... 480 V AC) Three Phase 1.5 A (550 ... 600 V AC) Three Phase 1.5 A | General Use Rating UL/CSA | (600 V AC) 0.25 A |
Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 18-10 AWG Stranded 1x 8 AWG | Ambient Air Temperature | Around the Enclosure 0 ... +40 °C Operation -25 ... +70 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C |
Ambient Air Temperature Compensation | Yes | Maximum Operating Altitude Permissible | 2000 m |
Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g | Resistance to Vibrations | 5g 3 ... 150 Hz |
Object Classification Code | F | ETIM 5 | EC000074 - Motor protective circuit-breaker |
ETIM 6 | EC000074 - Motor protection circuit-breaker | ETIM 7 | EC000074 - Motor protection circuit-breaker |
ETIM 8 | EC000074 - Motor protection circuit-breaker | eClass | V11.0 : 27370401 |
UNSPSC | 39121521 | IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
E-Number (Finland) | 3707832 | E-Number (Sweden) | 3110451 |
Manufacturer ID | 1SAM350010R1002 |