Product Model

OS250D22N1M1P

In Stock
Last updated: 2025/4/19
ABB OS250D22N1M1P

Selling Points

  • 1Reliable Short Circuit Protection: Provides effective short circuit protection with adjustable fuse rating.
  • 2Easy Installation: Snap-to-install design with adjustable mounting feet for top and side mounting.
  • 3Durable Construction: Protected to IP20, achieving IP65 with proper enclosure and handle.
  • 4Versatile Mounting Options: Suitable for DIN rail mounting with auxiliary contacts available.
  • 5High-Quality Materials: Black plastic ON/OFF handle and adjustable operating shaft included.
Product Details
OS250D22N1M1P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Pollution Degree
3
Product Net Width
260 mm
Product Net Height
199 mm
Product Net Depth / Length
154 mm
Product Net Weight
5.1 kg 11.2 lb
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 250 A
Conventional Thermal Current (Ithe)
Fully Enclosed 250 A
Fourth Pole Position
Left Side
Fourth Pole Type
Switched - With Solid Link
Fuse Size
NH0 NH1
Fuse System
DIN
Handle Type
Handle and shaft included
Mounting Type
Base mounting
Number of Poles
4
Operating Mode
Front Operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 13 W
Rated Conditional Short-Circuit Current (Inc)
(690 V) 80 kA
Rated Current (In)
Main Circuit 250 A
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(500 V) 250 A (690 V) 250 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 75 kW (400 V) 140 kW (415 V) 145 kW (500 V) 170 kW (690 V) 250 kW
Rated Operational Voltage
Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 8 kiloampere rms
Standards
IEC 60947-3
Switches Operating Mechanism
22 (Between the Poles)
Terminal Type
Lug terminals
Terminal Width
25 mm
Tightening Torque
30 ... 44 N·m
Tightening Torque
30 ... 44 N·m
Object Classification Code
Q
ETIM 8
EC001040 - Fuse switch disconnector
ETIM 9
EC001040 - Fuse switch disconnector
UNSPSC
39122233
IDEA Granular Category Code (IGCC)
5291 >> Fuse switch disconnector
eClass
V11.1 : 27371401
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3661211
Manufacturer ID
1SCA022757R8490

Specifications may be subject to change without notice