Product Model

OS400D12LRP

In Stock
Last updated: 2025/4/19
ABB OS400D12LRP

Selling Points

  • 1High Reliability: Built to withstand extreme conditions with self-cleaning and maintenance-free contacts.
  • 2Compact Design: Modular structure allows for easy installation in smaller enclosures, saving space and installation time.
  • 3Adjustable Shaft: Enables flexible installation depths without needing special cutting tools, reducing handle installation times by up to 50%.
  • 4Enhanced Safety: Interlocking fuse covers prevent opening while the switch is in the "ON" position, ensuring safety for personnel.
  • 5Compliant Standards: Meets DIN 43620 and IEC 60269-2 standards for high-performance operation in various environments.
Product Details
OS400D12LRP
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Pollution Degree
3
Product Net Width
400 mm
Product Net Height
194 mm
Product Net Depth / Length
201 mm
Product Net Weight
9.4 kg
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 400 A
Conventional Thermal Current (Ithe)
Fully Enclosed 400 A
Fuse Size
NH0 NH1 NH2
Fuse System
DIN
Handle Type
Pistol handle and shaft included
Mounting Type
Base mounting
Number of Poles
3
Operating Mode
Front Operated
Pollution Degree
3
Position of Line Terminals
Left In - Right Out
Power Loss
at Rated Operating Conditions per Pole 40 W
Rated Conditional Short-Circuit Current (Inc)
(690 V) 80 kA
Rated Current (In)
Main Circuit 400 A
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(500 V) 400 A (690 V) 400 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 132 kW (400 V) 220 kW (415 V) 230 kW (500 V) 280 kW (690 V) 400 kW
Rated Operational Voltage
Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 14 kiloampere rms
Standards
IEC 60947-3
Switches Operating Mechanism
12 (Between the Poles)
Terminal Type
Lug terminals
Terminal Width
25 mm
Tightening Torque
30 ... 44 N·m
Tightening Torque
30 ... 44 N·m
Object Classification Code
Q
ETIM 8
EC001040 - Fuse switch disconnector
ETIM 9
EC001040 - Fuse switch disconnector
UNSPSC
39122233
IDEA Granular Category Code (IGCC)
5291 >> Fuse switch disconnector
eClass
V11.1 : 27371401
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
1SCA022853R2280

Specifications may be subject to change without notice