Product Model

OS400D13N1P

In Stock
Last updated: 2025/4/17
ABB OS400D13N1P

Selling Points

  • 1Reliable 4-Pole Front-Operated Design: Ensures safe and efficient operation in industrial settings.
  • 2High Insulation Voltage (Ui) 1000 V: Provides robust electrical insulation for reliable performance.
  • 3Rated Operational Current AC-21A (Ie) 400 A: Supports high operational currents in various applications.
  • 4Welded Contact Protection: Enhances safety by protecting contacts from wear and tear.
  • 5Modular Construction: Facilitates easy installation and maintenance in industrial control panels.
Product Details
OS400D13N1P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Pollution Degree
3
Product Net Width
193 mm
Product Net Height
319 mm
Product Net Depth / Length
230 mm
Product Net Weight
8.4 kg
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 400 A
Conventional Thermal Current (Ithe)
Fully Enclosed 400 A
Fourth Pole Position
Left Side
Fourth Pole Type
Switched - With Solid Link
Fuse Size
NH0 NH1 NH2
Fuse System
DIN
Handle Type
Handle and shaft included
Mounting Type
Base mounting
Number of Poles
4
Operating Mode
Front Operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 30 W
Rated Conditional Short-Circuit Current (Inc)
(690 V) 80 kA
Rated Current (In)
Main Circuit 400 A
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(500 V) 400 A (690 V) 400 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 132 kW (400 V) 220 kW (415 V) 230 kW (500 V) 280 kW (690 V) 400 kW
Rated Operational Voltage
Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 14 kiloampere rms
Standards
IEC 60947-3
Switches Operating Mechanism
13 (Between the Poles)
Terminal Type
Lug terminals
Terminal Width
25 mm
Tightening Torque
30 ... 44 N·m
Tightening Torque
30 ... 44 N·m
Object Classification Code
Q
ETIM 8
EC001040 - Fuse switch disconnector
ETIM 9
EC001040 - Fuse switch disconnector
UNSPSC
39122233
IDEA Granular Category Code (IGCC)
5291 >> Fuse switch disconnector
eClass
V11.1 : 27371401
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
1SCA106322R1001

Specifications may be subject to change without notice