Selling Points

  • 1Reliable Motor Protection: Designed for extreme conditions to ensure long, reliable electrical life.
  • 2Self-Cleaning Contacts: Maintain performance without damaging the switch or affecting contact performance.
  • 3Modular Design: Easy and cost-efficient installation, maintenance, and use with adjustable shafts and snap-on auxiliary contacts.
  • 4Time-Saving Accessories: Adjustable shafts and mounting feet reduce installation time by up to 50%.
  • 5Enhanced Safety: Interlocking fuse covers prevent opening while the switch is in “ON” position, reducing the risk of electric shock to authorized personnel.
Product Details
OS630DS30
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Pollution Degree
3
Product Net Width
414 mm
Product Net Height
306 mm
Product Net Depth / Length
247 mm
Product Net Weight
13.9 kg
Cable Cross-Section
0.75 ... 10 mm²
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 630 A
Conventional Thermal Current (Ithe)
Fully Enclosed 570 A
Fuse Size
NH3
Fuse System
DIN
Handle Type
Handle and shaft not included
Mounting Type
Base mounting
Number of Poles
3P
Operating Mode
Side Operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out, Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 46 W
Rated Conditional Short-Circuit Current (Inc)
(690 V) 80 kA
Rated Current (In)
Main Circuit 630 A
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(500 V) 630 A (690 V) 630 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 630 A (500 V) 630 A (690 V) 630 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 630 A (500 V) 630 A (690 V) 630 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 200 kW (400 V) 355 kW (415 V) 355 kW (500 V) 450 kW (690 V) 630 kW
Rated Operational Voltage
Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 18 kiloampere rms
Standards
IEC 60947-3
Switches Operating Mechanism
30 (Right Side)
Terminal Type
Lug terminals
Terminal Width
39 mm
Tightening Torque
50 ... 75 N·m
Tightening Torque
50 ... 75 N·m
Object Classification Code
Q
ETIM 8
EC001040 - Fuse switch disconnector
ETIM 9
EC001040 - Fuse switch disconnector
UNSPSC
39122233
IDEA Granular Category Code (IGCC)
5291 >> Fuse switch disconnector
eClass
V11.1 : 27371401
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
1SCA108135R1001