Product Model

OT1000E01P

In Stock
Last updated: 2025/4/21
ABB OT1000E01P

Selling Points

  • 1High-Voltage Capability: Rated Insulation Voltage (Ui) up to 1000 volts according to IEC/EN 60664-1.
  • 2Efficient Design: Front-operated, base-mounted switch-disconnector with a black IP65 handle and shaft.
  • 3Enhanced Safety: Terminal bolt kit included for secure connections.
  • 4Compliance Standards: Meets IEC 60947-3 standards for switch-disconnectors.
  • 5Durable Construction: Rated Impulse Withstand Voltage (Uimp) of 12 kilovolts for robust performance.
Product Details
OT1000E01P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP00
Environmental Information
1SCC301233D0201
Pollution Degree
3
Product Net Width
174.5 mm
Product Net Height
306 mm
Product Net Depth / Length
167 mm
Product Net Weight
7.4 kg
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 1000 A
Conventional Thermal Current (Ithe)
Fully Enclosed 1000 A
Degree of Protection
Front IP00
Distance Between Phases
Standard
Handle Color
Black
Handle Type
Handle and shaft included
Lock Type
Yes
Mechanical Durability
6000
Mounting Type
Base mounting
Number of Poles
1P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 19 W
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A (1000 V) 1000 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Power AC-23A (Pe)
(400 ... 415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 110 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 50 kA
Special Functions
No
Standards
IEC 60947-3
Switches Operating Mechanism
Mechanism at the End of the Switch 01 (Left Side)
Terminal Type
Lug terminals
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
1SCA123134R1001

Specifications may be subject to change without notice