Product Model

OT1000E03N3P

In Stock
Last updated: 2025/4/25
ABB OT1000E03N3P

Selling Points

  • 1High Operational Voltage: Rated at 1000 V for reliable power distribution.
  • 2Robust Insulation: Withstood impulse voltage up to 12 kV and insulation voltage of 1000 V.
  • 3IP65 Protected Handle: Includes a black on-off plastic handle and shaft, protected against dust and water.
  • 4Adjustable Installation Depth: The shaft is adjustable for a range of installation depths.
  • 5High Current Capacity: Rated short-time withstand current of 50 kA rms for 1 second.
Product Details
OT1000E03N3P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP00
Environmental Information
1SCC301233D0201
Pollution Degree
3
Product Net Width
334.5 mm
Product Net Height
306 mm
Product Net Depth / Length
167 mm
Product Net Weight
18.9 kg
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 1000 A
Conventional Thermal Current (Ithe)
Fully Enclosed 1000 A
Degree of Protection
Front IP00
Distance Between Phases
Standard
Fourth Pole Position
Left Side
Fourth Pole Type
Detachable Neutral Link Integrated Into the Mechanism
Handle Color
Black
Handle Type
Handle and shaft included
Lock Type
Yes
Mechanical Durability
6000
Mounting Type
Base mounting
Number of Poles
3P+N
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 19 W
Rated Conditional Short-Circuit Current (Inc)
(1250 A fuse, 415 V) 80 kA (1250 A fuse, 500 V) 100 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A (1000 V) 1000 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Power AC-23A (Pe)
(400 ... 415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 110 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 50 kA
Special Functions
No
Standards
IEC 60947-3
Switches Operating Mechanism
Mechanism at the End of the Switch 03 (Left Side)
Terminal Type
Lug terminals
Terminal Width
50 mm
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3661602
Manufacturer ID
1SCA100761R1001

Specifications may be subject to change without notice