Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC301334D0201
Pollution Degree
3
Product Net Width
70 mm
Product Net Height
102.5 mm
Product Net Depth / Length
70 mm
Product Net Weight
0.412 kg
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x Cu 2.5…4 mm² Solid 1/2x Cu 2.5…6 mm² Flexible 1x Cu 2.5…70 mm² Flexible 2x Cu 2.5…25 mm² Stranded 1x Cu 2.5…70 mm² Stranded 2x Cu 2.5…25 mm²
Conventional Free-air Thermal Current (Ith)
100 A
Conventional Thermal Current (Ithe)
100 A
Degree of Protection
Front IP20
Handle Type
Handle not included
Maximum Mounted Auxiliary Contacts
4 NO, 4 NC
Mechanical Durability
Nr. Operations 100000
Mounting Type
Door mounting
Number of Poles
3P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 3.7 W
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (80 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC 60947-1 800 V
Rated Operational Current AC-21A (Ie)
(415 V) 100 A (690 V) 100 A (800 V AC) 80 A
Rated Operational Current AC-22A (Ie)
(415 V) 100 A (690 V) 100 A (800 V) 45 A
Rated Operational Current AC-23A (Ie)
(415 V) 100 A (690 V) 63 A
Rated Operational Power AC-23A (Pe)
(415 V) 55 kW (690 V) 55 kW
Rated Operational Voltage
Main Circuit 800 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 4.8 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 2.5 kA for 0.2 s 3.3 kA
Recommended Screw Driver
Main Circuit Hexagon 4
Special Functions
No
Standards
IEC60947-3 UL98 CSA C22.2 No.4
Switches Operating Mechanism
Mechanism on Top of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 6 N·m
Wire Stripping Length
Main Circuit 16-18 mm Main Circuit 0.63-0.71 in
Maximum Operating Voltage UL/CSA
600 V
Ampere Rating
100 A
Horsepower Rating UL/CSA
(110 ... 120 V AC) Single Phase 5 Hp (240 V AC) Single Phase 15 Hp (440 ... 480 V AC) Single Phase 25 Hp (550 ... 600 V AC) Single Phase 30 Hp (110 ... 120 V AC) Three Phase 10 Hp (240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 50 Hp (550 ... 600 V AC) Three Phase 60 Hp
Wire Size
1x 12-2/0 AWG 2x 12-4 AWG
Wire Stripping Length
Main Circuit 16-18 mm Main Circuit 0.63-0.71 in
Recommended Screw Driver
Main Circuit Hexagon 4
Tightening Torque
acc. IEC 60947-1 6 N·m
Tightening Torque UL/CSA
UL 53 lbf·in
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122233
IDEA Granular Category Code (IGCC)
5290 >> Disconnect switch
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
1SCA162515R1001

Specifications may be subject to change without notice