Product Model

OT1200U04

In Stock
Last updated: 2025/4/23
ABB OT1200U04

Selling Points

  • 1High Performance: Designed for reliable operation in extreme conditions.
  • 2Safety Features: Equipped with comprehensive inbuilt safety features, including finger-proof design and wielded contact protection.
  • 3Compliance: Meets EU Directive 2011/65/EU and Amendment 2015/863, ensuring RoHS compliance.
  • 4Versatile Mounting: Mountable in any position, including base, door, or panel mounting.
  • 5Technical Specifications: Rated for 1200A at 600V AC, with a maximum short-circuit making capacity of 92kA at 690V.
Product Details
OT1200U04
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP00
Environmental Information
1SCC301233D0201
Pollution Degree
3
Product Net Width
414.5 mm
Product Net Height
372 mm
Product Net Depth / Length
145.5 mm
Product Net Weight
22.2 kg
Degree of Protection
Front IP00
Distance Between Phases
Standard
Fourth Pole Position
Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Type
Handle and shaft not included
Lock Type
No
Mechanical Durability
6000
Mounting Type
Base mounting
Number of Poles
4P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 48 W
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 1250 A (500 V) 1250 A (690 V) 1250 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 710 kW (500 V) 900 kW (690 V) 1200 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 92 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 50 kA
Special Functions
No
Standards
IEC 60947-3 / UL 98 / CSA C22.2 NO.4
Switches Operating Mechanism
Mechanism at the End of the Switch 04 (Left Side)
Terminal Type
Lug terminals
Tightening Torque
acc. IEC 60947-1 56.5 N·m
Maximum Operating Voltage UL/CSA
600 V
Ampere Rating
1200 A
Tightening Torque
acc. IEC 60947-1 56.5 N·m
Tightening Torque UL/CSA
500 in·lb
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122233
IDEA Granular Category Code (IGCC)
5290 >> Disconnect switch
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
1SCA022860R7040