Product Model

OT125F8

In Stock
Last updated: 2025/4/22
ABB OT125F8

Selling Points

  • 1High-performance switch disconnector with 125A maximum current.
  • 2Compact design with IP20 protection for reliable operation.
  • 3Base mounting type for easy installation and flexibility.
  • 4Suitable for diverse applications with AC and DC ratings.
  • 5Available in multiples of 1 for flexible ordering options.
Product Details
OT125F8
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC301264D0201
Pollution Degree
3
Product Net Width
193 mm
Product Net Height
100 mm
Product Net Depth / Length
86 mm
Product Net Weight
1.1 kg
Cable Cross-Section
Cu 10 ... 70 mm²
Connecting Capacity Main Circuit
Flexible 1x Cu 10…70 mm² Stranded 1x Cu 10…70 mm²
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 125 A
Conventional Thermal Current (Ithe)
Fully Enclosed 125 A
Degree of Protection
Front IP20
Distance Between Phases
Standard
Fourth Pole Position
Left and Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Type
Knob Handle and shaft not included
Lock Type
No
Mechanical Durability
20000
Mounting Type
Base mounting
Number of Poles
8P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 6.3 W
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 90 A (500 V) 70 A (690 V) 50 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
Rated Operational Voltage
Main Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 2.5 kA
Recommended Screw Driver
Main Circuit Hexagon 4
Special Functions
No
Standards
IEC 60947-3
Switches Operating Mechanism
Mechanism on Top of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 6 N·m
Wire Stripping Length
Main Circuit 18-21 mm
Maximum Operating Voltage UL/CSA
600 V
Ampere Rating
100 A
Horsepower Rating UL/CSA
(acc. to UL 200 V) 25 Hp (acc. to UL 480 V) 50 Hp (acc. to UL 240 V) 30 Hp (acc. to UL 208 V) 25 Hp (acc. to UL 600 V) 50 Hp
Wire Stripping Length
Main Circuit 18-21 mm
Recommended Screw Driver
Main Circuit Hexagon 4
Tightening Torque
acc. IEC 60947-1 6 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3601416
E-Number (Norway)
4363575
E-Number (Sweden)
3134589
Manufacturer ID
1SCA105059R1001

Specifications may be subject to change without notice