  • 1High Current Rating: Handles up to 125A for reliable operation in demanding environments.
  • 2Door Mounting Flexibility: Designed for easy installation on enclosure or cabinet doors.
  • 3IP20 Protection: Front IP20 degree of protection ensures safe operation in various conditions.
  • 4Flexible Cable Capacity: Supports flexible cables with ferrules from 10 to 70mm².
  • 5Compact Design: Measures 96.5mm in width, 100mm in height, and 66.5mm in depth for space efficiency.
Product Details
OT125FT4N2
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC301264D0201
Pollution Degree
3
Product Net Width
96.5 mm
Product Net Height
100 mm
Product Net Depth / Length
66.5 mm
Product Net Weight
0.5 kg
Cable Cross-Section
Cu 10 ... 70 mm²
Connecting Capacity Main Circuit
Flexible 1x Cu 10…70 mm² Stranded 1x Cu 10…70 mm²
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 125 A
Conventional Thermal Current (Ithe)
Fully Enclosed 125 A
Degree of Protection
Front IP20
Distance Between Phases
Standard
Fourth Pole Position
Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Type
Handle and shaft not included
Lock Type
No
Mechanical Durability
20000
Mounting Type
Door mounting
Number of Poles
4P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 6.3 W
Rated Conditional Short-Circuit Current (Inc)
(125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 10 kA (63 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 90 A (500 V) 70 A (690 V) 50 A
Rated Operational Power AC-23A (Pe)
(220 ... 240 V) 22 kW (400 ... 415 V) 45 kW (500 V) 45 kW (690 V) 45 kW
Rated Operational Voltage
Main Circuit 750 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 3.6 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 2.5 kA
Recommended Screw Driver
Main Circuit Hexagon 4
Special Functions
No
Standards
IEC 60947-3
Switches Operating Mechanism
Mechanism on Top of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 6 N·m
Wire Stripping Length
Main Circuit 18-21 mm
Maximum Operating Voltage UL/CSA
600 V
Ampere Rating
100 A
Horsepower Rating UL/CSA
(acc. to UL 200 V) 25 Hp (acc. to UL 480 V) 50 Hp (acc. to UL 240 V) 30 Hp (acc. to UL 208 V) 25 Hp (acc. to UL 600 V) 50 Hp
Wire Stripping Length
Main Circuit 18-21 mm
Recommended Screw Driver
Main Circuit Hexagon 4
Tightening Torque
acc. IEC 60947-1 6 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3601418
E-Number (Norway)
4363547
E-Number (Sweden)
3171088
Manufacturer ID
1SCA105066R1001