ABB OT125GFCC6T

Selling Points

  • 1High-Performance Protection: Designed for 6-pole, 400V AC23, 125A applications.
  • 2Reliable Construction: Features a robust plastic enclosure with IP65 protection.
  • 3Easy Operation: Equipped with a black pistol handle for effortless control.
  • 4Interlocked Cover: Includes an interlocked cover for added safety and security.
  • 5Versatile Installation: Suitable for front mounting and distribution board installations.
Product Details
OT125GFCC6T
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
acc. to IEC 60529 IP65
Pollution Degree
3
Product Net Width
380 mm
Product Net Height
560 mm
Product Net Depth / Length
180 mm
Product Net Weight
8 kg
Cable Cross-Section
10 ... 70 mm²
Cable Entry Position
Top/Bottom
Cable Outlets Per Side
II-flange / II-flange
Connecting Capacity Main Circuit
Screw Clamp 10 ... 70 mm² Screw Clamp / PE Terminal 2pc,10 ... 70 mm²
Conventional Thermal Current (Ithe)
Fully Enclosed 125 A
Degree of Protection
acc. to IEC 60529 IP65
Enclosure Material
Plastic
Enclosure Type
Fibox
Handle Color
Black
Handle Type
Pistol handle
Impact Resistance Rating
Housing IK08
Maximum Mounted Auxiliary Contacts
2 NO, 2 NC
Mounted Auxiliary Contacts
2 NO, 2 NC
Neutral Type
No neutral terminal
Number of Auxiliary Contacts NC
2
Number of Auxiliary Contacts NO
2
Number of Poles
6P
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out
Rated Conditional Short-Circuit Current (Inc)
24 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 55 kW (500 V) 75 kW (690 V) 110 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V AC) 12 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 4 kA
Recommended Screw Driver
Main Circuit Hexagon 4
Standards
IEC 60947-1, -3
Terminal Type
Screw Terminals
Tightening Torque
Main Circuit 6 N·m
Wire Stripping Length
20 mm
Wire Stripping Length
20 mm
Recommended Screw Driver
Main Circuit Hexagon 4
Tightening Torque
Main Circuit 6 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122205
IDEA Granular Category Code (IGCC)
5166 >> Safety switch
eClass
V11.1 : 27371403
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
E-Number (Sweden)
3134577
Manufacturer ID
1SCA148668R1001

Specifications may be subject to change without notice