Product Model

OT125GLCC4TZ

In Stock
Last updated: 2025/4/19
ABB OT125GLCC4TZ

Selling Points

  • 1Built to withstand UV light, ensuring durability in outdoor conditions.
  • 2Offers high protection against solid particles and water ingress, making it suitable for harsh environments.
  • 3Equipped with an inbuilt gas pressure relief function to protect users from internal arcs.
  • 4Features a padlockable handle for secure operation and tamper prevention.
  • 5Constructed with a galvanized steel enclosure and polyester coating for added strength and durability.
Product Details
OT125GLCC4TZ
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
acc. to IEC 60529 IP65
Pollution Degree
3
Product Net Width
250 mm
Product Net Height
400 mm
Product Net Depth / Length
180 mm
Product Net Weight
9.6 kg
Cable Cross-Section
10 ... 70 mm²
Cable Entry Position
Top/Bottom
Cable Outlets Per Side
C-flange / C-flange, Knock-outs: 10mm, 12.5mm, 20.5mm, 25.5mm
Connecting Capacity Main Circuit
Screw Clamp 10 ... 70 mm² Screw Clamp / PE Terminal 2pc,10 ... 70 mm²
Conventional Thermal Current (Ithe)
Fully Enclosed 125 A
Degree of Protection
acc. to IEC 60529 IP65
Enclosure Material
Steel sheet
Enclosure Type
MSC
Handle Color
Black
Handle Type
Pistol handle
Impact Resistance Rating
Housing IK09
Maximum Mounted Auxiliary Contacts
2 NO, 2 NC
Mounted Auxiliary Contacts
1 NO, 1 NC
Neutral Type
Switchable neutral
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
1
Number of Poles
4P
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out
Rated Conditional Short-Circuit Current (Inc)
24 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 125 A (500 V) 125 A (690 V) 125 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 55 kW (500 V) 75 kW (690 V) 110 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V AC) 12 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 4 kA
Recommended Screw Driver
Main Circuit Hexagon 4
Standards
IEC 60947-1, -3
Terminal Type
Screw Terminals
Tightening Torque
Main Circuit 6 N·m
Wire Stripping Length
20 mm
Wire Stripping Length
20 mm
Recommended Screw Driver
Main Circuit Hexagon 4
Tightening Torque
Main Circuit 6 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122205
IDEA Granular Category Code (IGCC)
5166 >> Safety switch
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Sweden)
3134580
Manufacturer ID
1SCA148214R1001

Specifications may be subject to change without notice