Product Model

OT1600EP03P

In Stock
Last updated: 2025/4/22
ABB OT1600EP03P

Selling Points

  • 1High-Performance Design: Compact and efficient, designed for reliable operation in demanding environments.
  • 2Enhanced Safety Features: Padlockable handle in the OFF-position ensures secure shutdown, and IP65 protection for durability.
  • 3Integrated Terminal Bolt Kit: Simplifies installation and reduces maintenance needs.
  • 4Robust Construction: Built to withstand harsh conditions with a mechanical endurance of 20,000 operations.
  • 5Compliance with IEC Standards: Meets stringent IEC 60947 standards for insulation voltage and pollution degree 3.
Product Details
OT1600EP03P
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP00
Environmental Information
1SCC301233D0201
Pollution Degree
3
Product Net Width
334.5 mm
Product Net Height
372 mm
Product Net Depth / Length
167 mm
Product Net Weight
17.6 kg
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 1600 A
Conventional Thermal Current (Ithe)
Fully Enclosed 1600 A
Degree of Protection
Front IP00
Distance Between Phases
Standard
Handle Color
Black
Handle Type
Handle and shaft included
Lock Type
Yes
Mechanical Durability
6000
Mounting Type
Base mounting
Number of Poles
3P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 48 W
Rated Conditional Short-Circuit Current (Inc)
(1250 A fuse, 415 V) 80 kA (1250 A fuse, 500 V) 100 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 1250 A (500 V) 1250 A (690 V) 1250 A
Rated Operational Power AC-23A (Pe)
(400 ... 415 V) 710 kW (500 V) 900 kW (690 V) 1200 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 110 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 50 kA
Special Functions
No
Standards
IEC 60947-3
Switches Operating Mechanism
Mechanism at the End of the Switch 03 (Left Side)
Terminal Type
Lug terminals
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Utilization
Earthing Switch Use
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122217
IDEA Granular Category Code (IGCC)
5214 >> Rotary switch
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3601492
Manufacturer ID
1SCA118455R1001