Product Model

OT160EVAUR3TZ-L22

In Stock
Last updated: 2025/4/21
ABB OT160EVAUR3TZ-L22

Selling Points

  • 1High Current Rating: Handles up to 160A, suitable for demanding power distribution needs.
  • 2Compact Design: Panel mount design for easy installation in tight spaces.
  • 3Safety Features: Finger-proof design for improved safety and reduced risk of electrical shock.
  • 4Versatile Applications: Suitable for mechanical equipment, power distribution, switchgear, motor control centers, and photovoltaic power generation systems.
  • 5Compliance & Certifications: Meets UL98 and IEC standards, ensuring compliance with global safety regulations.
Product Details
OT160EVAUR3TZ-L22
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
acc. to IEC 60529 IP65
Pollution Degree
3
Product Net Width
400 mm
Product Net Height
600 mm
Product Net Depth / Length
230 mm
Product Net Weight
24.41 kg
Cable Entry Position
Down/Down
Cable Outlets Per Side
Blank / 4xring-flange, Knock-outs: 3x10mm, 12.5mm, 20.5mm, 25.5mm, 32.5mm
Connecting Capacity Main Circuit
Hole Diameter 8 mm Screw Clamp / PE Terminal 2pc,10 ... 70 mm²
Conventional Thermal Current (Ithe)
Fully Enclosed 160 A
Degree of Protection
acc. to IEC 60529 IP65
Enclosure Material
Steel sheet
Enclosure Type
MSC
Handle Color
Black
Handle Type
Pistol handle
Impact Resistance Rating
Housing IK09
Maximum Mounted Auxiliary Contacts
2 NO, 2 NC
Mechanical Durability
20000
Mounted Auxiliary Contacts
2 NO, 1 NC
Neutral Type
No neutral terminal
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
2
Number of Poles
3P
Pollution Degree
3
Position of Line Terminals
Bottom In - Bottom Out
Power Loss
at Rated Operating Conditions per Pole 3.2 W
Rated Conditional Short-Circuit Current (Inc)
40.5 kA
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 80 kW (500 V) 112 kW (690 V) 144 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 30 kA
Standards
IEC 60947-1, -3
Terminal Type
Bolt
Tightening Torque
acc. IEC 60947-1 6 N·m
Tightening Torque
acc. IEC 60947-1 6 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Manufacturer ID
1SCA153778R1001

Specifications may be subject to change without notice