Product Model
OT160GT30

Selling Points
- 1High Amperage Rating: 160A for efficient power handling.
- 2Compact Design: Dimensions of 130 mm H x 123 mm W x 73 mm D for easy installation.
- 3Safety Features: IP20 enclosure for protection against solid objects and accidental touch.
- 4Versatile Mounting: Base mounting type for flexible installation options.
- 5Compliance Certifications: Meets UL98, CSA C22.2 NO.4, and IEC 60947-3 standards for reliability and safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Degree of Protection | Front IP20 | Environmental Information | 1SCC301267D0201 |
Pollution Degree | 3 | Product Net Width | 123 mm |
Product Net Height | 130 mm | Product Net Depth / Length | 75 mm |
Product Net Weight | 0.8 kg | Cable Cross-Section | Cu 10 ... 70 mm² |
Conventional Free-air Thermal Current (Ith) | Π= 40 °C 160 A | Conventional Thermal Current (Ithe) | Fully Enclosed 160 A |
Degree of Protection | Front IP20 | Distance Between Phases | Standard |
Handle Type | Handle and shaft not included | Lock Type | No |
Mechanical Durability | 20000 | Mounting Type | Door mounting |
Number of Poles | 3P | Operating Mode | Front and side operated |
Pollution Degree | 3 | Position of Line Terminals | Top In - Bottom Out Bottom In - Top Out |
Power Loss | at Rated Operating Conditions per Pole 6.5 W | Rated Conditional Short-Circuit Current (Inc) | (200 A fuse, 500 V) 100 kA (200 A fuse, 690 V) 50 kA |
Rated Impulse Withstand Voltage (Uimp) | 12 kV | Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V |
Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A | Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A |
Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A | Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 45 kW (400 ... 415 V) 75 kW (500 V) 90 kW (690 V) 132 kW |
Rated Operational Voltage | Main Circuit 1000 V | Rated Short-Circuit Making Capacity (Icm) | (690 V) 12 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 4 kA | Special Functions | No |
Standards | IEC 60947-3 / UL 98 / CSA C22.2 NO.4 | Switches Operating Mechanism | Mechanism at the End of the Switch 30 (Right Side) |
Terminal Type | Screw Terminals | Tightening Torque | acc. IEC 60947-1 6 N·m |
Maximum Operating Voltage UL/CSA | 600 V | Ampere Rating | 125 A |
Horsepower Rating UL/CSA | (240 V AC) Single Phase 20 Hp (440 ... 480 V AC) Single Phase 30 Hp | Tightening Torque | acc. IEC 60947-1 6 N·m |
Tightening Torque UL/CSA | 53 in·lb | Object Classification Code | Q |
ETIM 8 | EC000216 - Switch disconnector | ETIM 9 | EC000216 - Switch disconnector (low voltage) |
eClass | V11.1 : 27371403 | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
Manufacturer ID | 1SCA138220R1001 |
Specifications may be subject to change without notice