Product Model
OT25F8

Selling Points
- 1High Performance in Low Voltage Applications: Designed for efficient motor control and power distribution.
- 28-Pole Configuration: Suitable for a wide range of electrical systems.
- 325A Rating: Handles significant current with reliability.
- 4IP20 Enclosure: Provides front-operated, non-fusible protection.
- 5DIN Rail Mountable: Easy installation in various industrial settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Degree of Protection | Front IP20 | Environmental Information | 1SCC301262D0201 |
Pollution Degree | 3 | Product Net Width | 96 mm |
Product Net Height | 68 mm | Product Net Depth / Length | 68 mm |
Product Net Weight | 0.27 kg | Cable Cross-Section | Cu 0.75 ... 10 mm² |
Connecting Capacity Main Circuit | Flexible with Ferrule 1x Cu 0.75â¦4 mm² Solid 1x Cu 0.75â¦6 mm² Flexible 1x Cu 0.75â¦10 mm² Stranded 1x Cu 0.75â¦10 mm² | Conventional Free-air Thermal Current (Ith) | Î = 40 °C 32 A |
Conventional Thermal Current (Ithe) | Fully Enclosed 32 A | Degree of Protection | Front IP20 |
Distance Between Phases | Standard | Fourth Pole Position | Left and Right Side |
Fourth Pole Type | Switched - Simultaneous Function | Handle Type | Knob Handle and shaft not included |
Lock Type | No | Mechanical Durability | 20000 |
Mounting Type | Base mounting | Number of Poles | 8P |
Operating Mode | Front operated | Pollution Degree | 3 |
Position of Line Terminals | Top In - Bottom Out Bottom In - Top Out | Power Loss | at Rated Operating Conditions per Pole 0.6 W |
Rated Conditional Short-Circuit Current (Inc) | (40 A fuse, â¤415V) 50 kA (25 A fuse, 690 V) 50 kA | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V | Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 25 A (500 V) 25 A (690 V) 25 A |
Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 25 A (500 V) 25 A (690 V) 25 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 20 A (500 V) 20 A (690 V) 11 A |
Rated Operational Current DC-21B (Ie) | (750 V) 25 A (550 V) 25 A (800 V) 16 A | Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 4 kW (400 ... 415 V) 9 kW (500 V) 9 kW (690 V) 9 kW |
Rated Operational Voltage | Main Circuit 750 V | Rated Short-Circuit Making Capacity (Icm) | (690 V) 0.71 kA |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 0.5 kA | Recommended Screw Driver | Main Circuit Pozidriv 2 |
Special Functions | No | Standards | IEC 60947-3 / UL 508 / CSA C22.2 No. 14 |
Switches Operating Mechanism | Mechanism on Top of the Switch | Terminal Type | Screw Terminals |
Tightening Torque | acc. IEC 60947-1 0.8 N·m | Wire Stripping Length | Main Circuit 9-10 mm |
Maximum Operating Voltage UL/CSA | 600 V | Ampere Rating | 30 A |
Horsepower Rating UL/CSA | (110 ... 120 V AC) Single Phase 1.5 Hp (240 V AC) Single Phase 3 Hp (440 ... 480 V AC) Single Phase 7.5 Hp (550 ... 600 V AC) Single Phase 10 Hp (220 ... 240 V AC) Three Phase 7,5 Hp (440 ... 480 V AC) Three Phase 15 Hp (550 ... 600 V AC) Three Phase 20 Hp | Wire Stripping Length | Main Circuit 9-10 mm |
Recommended Screw Driver | Main Circuit Pozidriv 2 | Tightening Torque | acc. IEC 60947-1 0.8 N·m |
Tightening Torque UL/CSA | 7 in·lb | Object Classification Code | Q |
ETIM 8 | EC000216 - Switch disconnector | ETIM 9 | EC000216 - Switch disconnector (low voltage) |
UNSPSC | 39122233 | IDEA Granular Category Code (IGCC) | 5290 >> Disconnect switch |
eClass | V11.1 : 27371403 | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
E-Number (Finland) | 3601434 | E-Number (Norway) | 4363570 |
Manufacturer ID | 1SCA104882R1001 |
Specifications may be subject to change without notice