Product Model

OT400DFCC6BA

In Stock
Last updated: 2025/4/24
ABB OT400DFCC6BA

Selling Points

  • 1IP65 Protection: Built to withstand low-pressure water jets and ensure reliability in both outdoor and indoor applications.
  • 2UV Resistant: Made from high-quality, UV-resistant materials to maintain performance under harsh environmental conditions.
  • 3Padlockable Handle: Equipped with a padlockable handle for secure operation, featuring a shackle for up to six padlocks.
  • 4Interlocked Cover: Includes an interlocked cover for enhanced safety, with the option to defeat the interlock if needed.
  • 5N and PE Terminals: Includes N and PE terminals for secure electrical connections, ensuring safe and dependable performance.
Product Details
OT400DFCC6BA
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
acc. to IEC 60529 IP65
Pollution Degree
3
Product Net Width
560 mm
Product Net Height
760 mm
Product Net Depth / Length
250 mm
Product Net Weight
26.83 kg
Cable Entry Position
Top/Bottom
Cable Outlets Per Side
2xII-flange / 2xII-flange
Connecting Capacity Main Circuit
Hole Diameter 10 mm Screw Clamp / PE Terminal 4pc,25 ... 120 mm²
Conventional Thermal Current (Ithe)
Fully Enclosed 400 A
Degree of Protection
acc. to IEC 60529 IP65
Enclosure Material
Plastic
Handle Color
Red / Yellow
Handle Type
Pistol handle
Impact Resistance Rating
Housing IK08
Maximum Mounted Auxiliary Contacts
4 NO, 2 NC
Mounted Auxiliary Contacts
0 NO, 0 NC
Neutral Type
Detachable neutral
Number of Auxiliary Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Poles
6P
Pollution Degree
3
Power Loss
at Rated Operating Conditions per Pole 10 W
Rated Conditional Short-Circuit Current (Inc)
61.5 kA
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 400 A (690 V) 400 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 230 kW (500 V) 280 kW (690 V) 400 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(1000 V AC) 65 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 15 kA
Recommended Screw Driver
Main Circuit M10
Standards
IEC 60947-1, -3
Tightening Torque
Main Circuit 44 N·m
Recommended Screw Driver
Main Circuit M10
Tightening Torque
Main Circuit 44 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122205
IDEA Granular Category Code (IGCC)
5166 >> Safety switch
eClass
V11.1 : 27371403
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Manufacturer ID
1SCA022845R2090

Specifications may be subject to change without notice