Product Model
OT400DUUR3TZ-L51

Selling Points
- 1Interlocked Cover for Enhanced Safety: The OT400DUUR3TZ-L51 features an interlocked cover to prevent unauthorized access.
- 2Padlockable Handle: The handle is padlockable for added security, allowing only authorized personnel to operate the switch.
- 3Steel Sheet Enclosure: Constructed with a durable steel sheet enclosure, ensuring robustness and longevity.
- 4IP65 Rating: Designed with an IP65 rating, providing protection against dust and water ingress.
- 5Mounting Auxiliary Contact: Equipped with mounted auxiliary contact (2NO1NC) for versatile application options.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Degree of Protection | acc. to IEC 60529 IP65 | Pollution Degree | 3 |
Product Net Width | 400 mm | Product Net Height | 800 mm |
Product Net Depth / Length | 230 mm | Product Net Weight | 29.85 kg |
Cable Entry Position | Down/Down | Cable Outlets Per Side | Blank / 4xring-flange, Knock-outs: 3x10mm, 12.5mm, 20.5mm, 25.5mm, 32.5mm |
Connecting Capacity Main Circuit | Hole Diameter 10 mm Screw Clamp / PE Terminal 4pc,25 ... 120 mm² | Conventional Thermal Current (Ithe) | Fully Enclosed 400 A |
Degree of Protection | acc. to IEC 60529 IP65 | Enclosure Material | Steel sheet |
Enclosure Type | MSC | Handle Color | Black |
Handle Type | Pistol handle | Impact Resistance Rating | Housing IK09 |
Maximum Mounted Auxiliary Contacts | 2 NO, 2 NC | Mechanical Durability | 16000 |
Mounted Auxiliary Contacts | 2 NO, 1 NC | Neutral Type | No neutral terminal |
Number of Auxiliary Contacts NC | 1 | Number of Auxiliary Contacts NO | 2 |
Number of Poles | 3P | Pollution Degree | 3 |
Position of Line Terminals | Bottom In - Bottom Out | Power Loss | at Rated Operating Conditions per Pole 10 W |
Rated Conditional Short-Circuit Current (Inc) | 61.5 kA | Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V |
Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A |
Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 220 kW (500 V) 280 kW (690 V) 355 kW | Rated Operational Voltage | Main Circuit 1000 V |
Rated Short-Circuit Making Capacity (Icm) | (690 V) 65 kA | Standards | IEC 60947-1, -3 |
Terminal Type | Bolt | Tightening Torque | acc. IEC 60947-1 44 N·m |
Tightening Torque | acc. IEC 60947-1 44 N·m | Object Classification Code | Q |
ETIM 8 | EC000216 - Switch disconnector | WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
Manufacturer ID | 1SCA153882R1001 |
Specifications may be subject to change without notice