Selling Points

  • 1High-Performance Safety: Equipped with integrated safety features like mechanical interlock and padlockable handle.
  • 2IP65 Protection: Black plastic handle and shaft provide excellent protection against dust and water.
  • 3Robust Construction: Designed for heavy-duty use with a conventional free-air thermal current of 400 A.
  • 4Versatile Installation: Adjustable shaft for various installation depths and easy installation process.
  • 5Compliance and Certifications: Meets EU Directive 2011/65/EU and has CE, UL, and CSA approvals.
Product Details
OT400E13CP
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC303050D0201
Pollution Degree
3
Product Net Width
265 mm 10.43 in
Product Net Height
185 mm 7.28 in
Product Net Depth / Length
203 mm 7.99 in
Product Net Weight
7.415 kg 16.35 lb
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 400 A
Conventional Thermal Current (Ithe)
Fully Enclosed 400 A
Degree of Protection
Front IP20
Distance Between Phases
Standard
Fourth Pole Position
Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Color
Black
Handle Type
Handle and shaft included
Mounting Type
Base mounting
Number of Poles
4P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out, Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 10 W
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A
Rated Operational Current AC-31B (Ie)
(380 ... 415 V) 400 A
Rated Operational Current AC-33B (Ie)
(380 ... 415 V) 400 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 220 kW (500 V) 280 kW (690 V) 400 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 15 kiloampere rms
Switches Operating Mechanism
Mechanism Between the Poles 13 (Between the Poles)
Terminal Type
Screw Terminals
Terminal Width
25 mm
Tightening Torque
acc. IEC 60947-1 30 ... 44 N·m
Transition Type
Open
Ampere Rating
400 A
Tightening Torque
acc. IEC 60947-1 30 ... 44 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3641538
Manufacturer ID
1SCA022777R0500