Product Model

OT630KLCC6AZ

In Stock
Last updated: 2025/4/27
ABB OT630KLCC6AZ

Selling Points

  • 1High Performance: Rated for 570 A at 500 V, ensuring reliable operation in demanding environments.
  • 2Enhanced Safety: Meets IP65 protection standards, providing robust protection against dust and water.
  • 3Durable Construction: Built with a steel enclosure, ensuring long-lasting durability and resistance to harsh conditions.
  • 4Easy Installation: Features padlockable handles and cable outlets for secure and efficient setup.
  • 5Versatile Application: Suitable for 3-, 4-, and 5-wire systems, making it adaptable to various industrial needs.
Product Details
OT630KLCC6AZ
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
acc. to IEC 60529 IP65
Pollution Degree
3
Product Net Width
800 mm
Product Net Height
1000 mm
Product Net Depth / Length
230 mm
Product Net Weight
47.1 kg
Cable Entry Position
Top/Bottom
Cable Outlets Per Side
4xC-flange / 4xC-flange, Knock-outs: 2x10mm, 12.5mm, 20.5mm, 25.5mm, 32.5mm
Connecting Capacity Main Circuit
Hole Diameter 12 mm Screw Clamp / PE Terminal 16pc,25 ... 120 mm²
Conventional Thermal Current (Ithe)
Fully Enclosed 570 A
Degree of Protection
acc. to IEC 60529 IP65
Enclosure Material
Steel sheet
Handle Color
Red / Yellow
Handle Type
Pistol handle
Impact Resistance Rating
Housing IK09
Maximum Mounted Auxiliary Contacts
4 NO, 4 NC
Mounted Auxiliary Contacts
4 NO, 2 NC
Neutral Type
No neutral terminal
Number of Auxiliary Contacts NC
2
Number of Auxiliary Contacts NO
4
Number of Poles
6P
Pollution Degree
3
Power Loss
at Rated Operating Conditions per Pole 25 W
Rated Conditional Short-Circuit Current (Inc)
90 kA
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 570 A (500 V) 570 A (690 V) 570 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 570 A (500 V) 570 A (690 V) 570 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 315 kW (500 V) 400 kW (690 V) 560 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(1000 V AC) 80 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Recommended Screw Driver
Main Circuit M12
Standards
IEC 60947-1, -3
Tightening Torque
Main Circuit 75 N·m
Recommended Screw Driver
Main Circuit M12
Tightening Torque
Main Circuit 75 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122205
IDEA Granular Category Code (IGCC)
5166 >> Safety switch
eClass
V11.1 : 27371403
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Manufacturer ID
1SCA022512R8620

Specifications may be subject to change without notice