Product Model

OTM100F4CMA24D

In Stock
Last updated: 2025/4/22
ABB OTM100F4CMA24D

Selling Points

  • 1Compact design for easy installation in confined spaces.
  • 2Reliable performance tested according to IEC 60947-3 and IEC 60947-6-1 standards.
  • 3Safe operation with finger-safe construction and mechanical/electrical locking options.
  • 4Versatile 3- and 4-pole switches suitable for various applications, including GenSet applications.
  • 5Enhanced logistics with a wide supply voltage range for effortless design work.
Product Details
OTM100F4CMA24D
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Pollution Degree
3
Product Net Width
283 mm 11.14 in
Product Net Height
100 mm 3.94 in
Product Net Depth / Length
116 mm 4.57 in
Product Net Weight
1.86 kg 4.1 lb
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 115 A
Conventional Thermal Current (Ithe)
Fully Enclosed 115 A
Degree of Protection
Front IP20
Distance Between Phases
Standard
Fourth Pole Position
Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Color
Black
Handle Type
Direct mounted handle
Motor Operational Voltage
24 V DC
Mounting Type
Base mounting
Number of Poles
4P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out, Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 4 W
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 100 A (500 V) 100 A (690 V) 100 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 100 A (500 V) 100 A (690 V) 100 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 80 A (500 V) 60 A (690 V) 40 A
Rated Operational Current AC-31B (Ie)
(380 ... 415 V) 100 A
Rated Operational Current AC-33B (Ie)
(380 ... 415 V) 80 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 37 kW (500 V) 37 kW (690 V) 37 kW
Rated Operational Voltage
Main Circuit 800 V
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 2.5 kiloampere rms
Switches Operating Mechanism
Mechanism at the End of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 6 N·m
Transition Type
Open
Tightening Torque
acc. IEC 60947-1 6 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3601575
Manufacturer ID
1SCA124066R1001

Specifications may be subject to change without notice