Product Model
OTM1600E4CM230C

Selling Points
- 1High-performance motorized operation for efficient switching.
- 2Includes a handle for manual operation and bolt kit with nut and washers.
- 3Rated insulation voltage of 1000 V and impulse withstand voltage of 12 kV.
- 4Conventional free-air thermal current (Ith) of 1600 A at 40°C.
- 5Designed with a robust construction for reliable operation in harsh environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Degree of Protection | Front IP20 | Environmental Information | 1SCC303036D0202 |
Pollution Degree | 3 | Product Net Width | 587 mm 23.11 in |
Product Net Height | 372 mm 14.65 in | Product Net Depth / Length | 372 mm 14.65 in |
Product Net Weight | 69 kg 152.12 lb | Conventional Free-air Thermal Current (Ith) | Π= 40 °C 1600 A |
Degree of Protection | Front IP20 | Distance Between Phases | Standard |
Fourth Pole Position | Right Side | Fourth Pole Type | Switched - Simultaneous Function |
Handle Color | Black | Handle Type | Direct mounted handle |
Motor Operational Voltage | 220 ... 240 V AC | Mounting Type | Base mounting |
Number of Poles | 4P | Operating Mode | Front operated |
Pollution Degree | 3 | Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
Power Loss | at Rated Operating Conditions per Pole 48 W | Rated Impulse Withstand Voltage (Uimp) | 12 kV |
Rated Insulation Voltage (Ui) | 1000 V | Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A |
Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A |
Rated Operational Current AC-31B (Ie) | (380 ... 415 V) 1600 A | Rated Operational Current AC-33B (Ie) | (380 ... 415 V) 1000 A |
Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 710 kW (500 V) 900 kW (690 V) 1200 kW | Rated Operational Voltage | Main Circuit 1000 V |
Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kiloampere rms | Switches Operating Mechanism | Mechanism at the End of the Switch |
Terminal Type | Screw Terminals | Tightening Torque | acc. IEC 60947-1 50 ... 75 N·m |
Transition Type | Open | Tightening Torque | acc. IEC 60947-1 50 ... 75 N·m |
Object Classification Code | Q | ETIM 8 | EC000216 - Switch disconnector |
ETIM 9 | EC000216 - Switch disconnector (low voltage) | eClass | V11.1 : 27371403 |
WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) | E-Number (Finland) | 3641792 |
Manufacturer ID | 1SCA112704R1001 |
Specifications may be subject to change without notice