Product Model

OTM200E3WCM48D

In Stock
Last updated: 2025/4/18
ABB OTM200E3WCM48D

Selling Points

  • 1High-Performance Operation: Designed for reliable and efficient operation in a variety of environments.
  • 2Advanced Safety Features: Equipped with comprehensive inbuilt safety features, including mechanical interlock for safe operations.
  • 3Robust Design: Constructed to withstand harsh conditions with a high dielectric strength and impulse withstand voltage.
  • 4Versatile Application: Suitable for a wide range of applications, including manual change-over and transfer switches.
  • 5Durable Build: Built to last with a high mechanical endurance, capable of withstanding up to 16,000 operations.
Product Details
OTM200E3WCM48D
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC303036D0202
Pollution Degree
3
Product Net Width
296 mm 11.65 in
Product Net Height
170 mm 6.69 in
Product Net Depth / Length
197 mm 7.76 in
Product Net Weight
5.6 kg 12.35 lb
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 200 A
Conventional Thermal Current (Ithe)
Fully Enclosed 200 A
Degree of Protection
Front IP20
Distance Between Phases
Wide phase distance
Handle Color
Black
Handle Type
Direct mounted handle
Motor Operational Voltage
48 V DC
Mounting Type
Base mounting
Number of Poles
3P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out, Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 4 W
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 200 A (500 V) 200 A (690 V) 200 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 200 A (500 V) 200 A (690 V) 200 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 200 A (500 V) 200 A (690 V) 200 A
Rated Operational Current AC-31B (Ie)
(380 ... 415 V) 200 A
Rated Operational Current AC-33B (Ie)
(380 ... 415 V) 200 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 110 kW (500 V) 132 kW (690 V) 200 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 8 kiloampere rms
Switches Operating Mechanism
Mechanism at the End of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 15 ... 22 N·m
Transition Type
Open
Tightening Torque
acc. IEC 60947-1 15 ... 22 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3641718
Manufacturer ID
1SCA022846R3700

Specifications may be subject to change without notice