Product Model

OTM200E4WCM230C

In Stock
Last updated: 2025/4/23
ABB OTM200E4WCM230C

Selling Points

  • 1High insulation voltage of 1000 V for reliable operation.
  • 2Robust construction with a pollution degree of 3 for harsh environments.
  • 3Easy installation with a manually operated switch via a handle.
  • 4Rated impulse withstand voltage of 12 kV for enhanced durability.
  • 5Suitable for applications requiring high operational currents up to 200 A.
Product Details
OTM200E4WCM230C
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC303036D0202
Pollution Degree
3
Product Net Width
339 mm 13.35 in
Product Net Height
170 mm 6.69 in
Product Net Depth / Length
197 mm 7.76 in
Product Net Weight
5 kg 11.02 lb
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 200 A
Conventional Thermal Current (Ithe)
Fully Enclosed 200 A
Degree of Protection
Front IP20
Distance Between Phases
Wide phase distance
Fourth Pole Position
Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Color
Black
Handle Type
Direct mounted handle
Motor Operational Voltage
220 ... 240 V AC
Mounting Type
Base mounting
Number of Poles
4P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out, Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 4 W
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 200 A (500 V) 200 A (690 V) 200 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 200 A (500 V) 200 A (690 V) 200 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 200 A (500 V) 200 A (690 V) 200 A
Rated Operational Current AC-31B (Ie)
(380 ... 415 V) 200 A
Rated Operational Current AC-33B (Ie)
(380 ... 415 V) 200 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 110 kW (500 V) 132 kW (690 V) 200 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 8 kiloampere rms
Switches Operating Mechanism
Mechanism at the End of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 15 ... 22 N·m
Transition Type
Open
Tightening Torque
acc. IEC 60947-1 15 ... 22 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3641724
Manufacturer ID
1SCA022846R7870

Specifications may be subject to change without notice