Product Model

OTM250E3WCM24D

In Stock
Last updated: 2025/4/17
ABB OTM250E3WCM24D

Selling Points

  • 1Designed for efficient and reliable operation in various electrical applications.
  • 2Built with durable materials to withstand harsh environmental conditions.
  • 3Ensures smooth and quick change-over operations, minimizing downtime.
  • 4Suitable for a wide range of electrical systems, including 3-phase and single-phase configurations.
  • 5Meets international standards for electrical safety and performance (e.g., IEC 60947-3, UL508).
Product Details
OTM250E3WCM24D
ABB

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Degree of Protection
Front IP20
Environmental Information
1SCC303036D0202
Pollution Degree
3
Product Net Width
296 mm 11.65 in
Product Net Height
170 mm 6.69 in
Product Net Depth / Length
197 mm 7.76 in
Product Net Weight
5.6 kg 12.35 lb
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 250 A
Conventional Thermal Current (Ithe)
Fully Enclosed 250 A
Degree of Protection
Front IP20
Distance Between Phases
Wide phase distance
Handle Color
Black
Handle Type
Direct mounted handle
Motor Operational Voltage
24 V DC
Mounting Type
Base mounting
Number of Poles
3
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out, Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 6.5 W
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 250 A (500 V) 250 A (690 V) 250 A
Rated Operational Current AC-31B (Ie)
(380 ... 415 V) 250 A
Rated Operational Current AC-33B (Ie)
(380 ... 415 V) 250 A
Rated Operational Power AC-23A (Pe)
(380 ... 415 V) 140 kW (500 V) 170 kW (690 V) 250 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 8 kiloampere rms
Switches Operating Mechanism
Mechanism at the End of the Switch
Terminal Type
Screw Terminals
Tightening Torque
acc. IEC 60947-1 15 ... 22 N·m
Transition Type
Open
Tightening Torque
acc. IEC 60947-1 15 ... 22 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
UNSPSC
39122214
IDEA Granular Category Code (IGCC)
5208 >> Controller switch
eClass
V11.1 : 27371403
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
E-Number (Finland)
3641735
Manufacturer ID
1SCA022846R4420

Specifications may be subject to change without notice